7.2 Search Interface of the Equipment
8. NOTES ABOUT OPTICAL CONNECTION
8.1 Please Carefully Clear All The Fiber Optic Connectors And
Connectors Before Connection.
Cleaning Guide:
8.1.1 Fiber Optical Jumper
Removal the dust cap of fiber optic connector, pay attention to confirm the
optical connector is a APC surface;
The tips of cleaning fiber optic connector is to use a dedicated and dry cloth
without velveteen (the company 5Kimwipes ®’s fine cloth); In addition,
preferably adopt special microscope (at 100 times, 200 times) to check the
cleanliness of fiber optic connector surface or blemish.
Pay attention to maintaining the fiber optic connectors is clean;
Fiber optic connectors (flange) is clean;
You can use a dedicated compressed gas to clean the surface of fiber optic
connector;
You can remove the dust which is less than 0.2 microns, better without residue;
Hold the tank of compressed air from the connector about 6 inches, alignment
flange, and press the nozzle switch shortly times, so you can clean the connector
completely;
If there is no dedicated compressed air, the 2.5 mm cotton swab for cleaning can
also be used to clean the optical transmitter connectors, or remove the flange
10