Table 1: Varium C1100 Compute Adaptor Features (cont'd)

Adaptor Component

Varium C1100

Power Management

Power management with system management bus (SMBus)

voltage, current, and temperature monitoring

External Power Sources

75W PCIe slot functional with PCIe slot power only.

Provisioned with auxiliary power connector. However, the

adaptor is thermally designed to support 150W.

Configuration Options

1 Gb Quad-SPI flash memory:
Ult device configurable over USB/JTAG and Quad-

SPI configuration flash memory

UART

UART access through the micro-USB connector

Minimum System Requirements

The minimum system requirements for running the Varium C1100 compute adaptor are listed in
the following table.

Table 2: Minimum System Requirements

Component

Requirement

Motherboard

PCI Express

®

 3.0-compliant with one full-height x16 slot.

System power supply

150W via PCI Express slot connection and 8-pin PCI Express auxiliary power.

Operating system

For the latest OS support, see XRT Release Notes (

UG1451

).

System memory

For deployment installations, a minimum of 16 GB plus application memory

requirements is required.
For development installations, a minimum of 64 GB of system memory is

required, but 80 GB is recommended.

Internet connection

Required for downloading drivers and utilities.

Hard disk space

Satisfy the minimum system requirements for your operating system.

Licensing

None required for application deployment.

For details on the acceptable environmental conditions, see the Varium C1100 Compute Adaptor
Data Sheet
 (

DS1003

).

Chapter 1: Introduction

UG1525 (v1.1) March 8, 2022

 

www.xilinx.com

Varium C1100 Compute Adaptor Installation Guide

 4

Send Feedback

Содержание Varium C1100

Страница 1: ...sive language from our products and related collateral We ve launched an internal initiative to remove language that could exclude people or reinforce historical biases including terms embedded in our...

Страница 2: ...Deployment Package Installation Procedures on Ubuntu 14 Chapter 5 Card Bring Up and Validation 17 Environment Setup 17 Running lspci 17 Confirm Firmware Installation 18 Card Validation 19 Chapter 6 T...

Страница 3: ...lications By installing the Varium C1100 compute adaptor with both the deployment and development software on a single machine you can configure a system for developing and running compute application...

Страница 4: ...uirements Component Requirement Motherboard PCI Express 3 0 compliant with one full height x16 slot System power supply 150W via PCI Express slot connection and 8 pin PCI Express auxiliary power Opera...

Страница 5: ...cket QSFP28 Inerfaces Micro USB Connector PCIe Connector AUX Power Connector Note Varium C1100 compute adaptor is designed to be installed into a data center server where controlled air flow provides...

Страница 6: ...mputer server clean and clear of debris Before opening the computer system cover unplug the power cord Dispositif de S curit Pour assurer votre s curit personnelle et la s curit de votre quipement Mai...

Страница 7: ...lors du retrait et remplacement des composants Pour pr venir les dommages dus aux ESD Utilisez une sangle de poignet ou de cheville anti ESD et assurez vous qu elle est en contact avec la peau Branch...

Страница 8: ...eils lectronique sensibles et fragiles l quipement doit tre install par un technicien certifi seulement Cet quipement est destin tre install dans un lieu d acc s restreint WICHTIG Die adaptern Varium...

Страница 9: ...50W Consult your computer documentation for additional information 6 Re install the computer casing 7 Connect the power cord and turn on the computer WARNING Do not power on a passively cooled card wi...

Страница 10: ...e a message similar to the previous one see Chapter 6 Troubleshooting Chapter 3 Adaptor Installation Procedures UG1525 v1 1 March 8 2022 www xilinx com Varium C1100 Compute Adaptor Installation Guide...

Страница 11: ...the Getting Started tab of the respective Alveo card landing page Varium C1100 Product Page If you encounter any issues during installation see Chapter 6 Troubleshooting IMPORTANT Root access is requ...

Страница 12: ...ployment target platform tar gz file into a single directory The location of the directory is not important however the directory should not contain any other files 7 Install the deployment packages F...

Страница 13: ...GA IMPORTANT Be sure to fully power off the machine and then power it on again The image will not boot from flash if the machine is only rebooted IMPORTANT Assurez vous d teindre compl tement la machi...

Страница 14: ...rom the Getting Started tab of the Varium C1100 compute adaptor product page download the XRT and deployment target platform installation packages associated with your OS and version To download the p...

Страница 15: ...terminal while the firmware is flashing as this can cause the card to become inoperable IMPORTANT N entrez pas Ctrl c dans le terminal lorsque le micrologiciel clignote car cela pourrait rendre la ca...

Страница 16: ...command separately for each card A message similar to the following will be displayed after a successful SC firmware update where the device management BDF is given in square brackets Report 0000 af...

Страница 17: ...ncluding memory PCIe platform name and system information See xbutil and xbmgmt Note Utility command line help can always be obtained using the help option Environment Setup Set the environment to use...

Страница 18: ...hysical functions found management and user For additional details see XRT and Vitis Platform Overview Confirm Firmware Installation When a card has successfully been installed and the firmware has be...

Страница 19: ...Validation Card installation can be validated using the xbutil validate command This command performs various tests and checks on the card including PCIe link status SC version status memory and band...

Страница 20: ...00 1 SC version Description Check if SC firmware is up to date Test Status PASSED Test 4 0000 af 00 1 Verify kernel Description Run Hello World kernel test Xclbin opt xilinx firmware u55n gen3x4 xdma...

Страница 21: ...D Test 10 0000 af 00 1 Host memory bandwidth test Description Run bandwidth kernel when host memory is enabled Details Host memory is not enabled Test Status SKIPPED Test 11 0000 af 00 1 vcu Descripti...

Страница 22: ...cal device user bdf Where user BDF is the card to be programmed To obtain the device management BDF see Displaying Card BDF Values An example of the output is shown below Electrical Max Power 225 Watt...

Страница 23: ...so known as golden This requires that XRT release 2020 1 or later is installed on the same system as the Varium C1100 compute adaptor For more information see AR71757 Appendix A Reverting the Card to...

Страница 24: ...sign Tools DocNav At the Linux command prompt enter docnav Xilinx Design Hubs provide links to documentation organized by design tasks and other topics which you can use to learn key concepts and addr...

Страница 25: ...k for more information Confirm Firmware Installation New topic to replace Running xbmgmt flash scan Card Validation New topic to replace xbutil validate Known Issues Updated command and log 09 17 2021...

Страница 26: ...se refer to Xilinx s Terms of Sale which can be viewed at https www xilinx com legal htm tos AUTOMOTIVE APPLICATIONS DISCLAIMER AUTOMOTIVE PRODUCTS IDENTIFIED AS XA IN THE PART NUMBER ARE NOT WARRANTE...

Отзывы: