The 3 available filter types for the high frequency crossover point (low pass) are:
Butterworth, Linkwitz Riley or B essel.
FRQH:
The f ilter c ut-off frequency for the high frequency crossover point (low pass) ranges from 20
to 30kHz in either 1Hz steps or 1/36 octave steps. The frequency steps can be selected in
the
System Menu
.
Please refer to page 21 for more details.
SLPH:
The filter slope for high frequency crossover point (low pass) ranges from 6 to 48dB/octave.
If the selected filter type is Linkwitz Riley, the available slopes are 12, 24, 36 or 48
dB/o ctave only.
Input Compressor
THRESH:
The compressor threshold ranges from -20 to +20dBu in 0.5dB steps.
ATTACK:
The compressor attack time ranges from 0.3 to 1ms in 0.1ms steps, then ranges from 1 to
100ms in 1ms steps .
RELEASE:
The compressor release time can be set at 2X, 4X, 8X, 16X or 32X the attack time.
RATIO:
The compressor ratio is the slope in which the signal is compressed. It ranges from 1:1 to
1:40.
Input/Output Channel Name
NAME:
A 6 characters name can be assigned to each channel.
Output Limiter
THRESH:
The limiter threshold ranges from -20 to +20dBu in 0.5dB steps.
ATTACK:
The limiter attack time ranges from 0.3 to 1ms in 0.1ms steps, then ranges from 1 to 100ms
in 1ms steps.
RELEASE:
The limiter release time can be set at 2X, 4X, 8X, 16X or 32X the attack time.
Output Source
IN1-8:
This sets the input channel source for the current output channel.
It can be used to mix
the input source (in dB) or disable it (Off). If more than one input sources are enabled,
they will be added together as the source for the current output channel.