Fault phenomenon: no PRE function (after turning on PRE, the amplitude-frequency curve of
network analysis does not rise)
Maintenance methods:
The fault phenomena are as follows:
During the network analysis test, turn on/ off the PRE function, and the
amplitude of the amplitude-frequency curve will not change (or
become low)
Maintenance methods:
The instrument settings are as follows:
Name
Setting Parameters
Parameter 1
Parameter 2
Parameter
3
Signal Source
Frequency:
14.271MHz
Amplitude:
-20dBm
/
Oscilloscope
Time base: 50ns
Y-axis:
100mV
X10 gear
After PRE is turned on, the measured data at each checkpoint shall be
as follows:
Checkpoint
Frequency
MHz
Amplitude
mVpp
Name
A12
14.271
50
Amplifier input
A14
14.271
680
Amplifier
output
If there is a great difference between the measured signal amplitude
and the standard data in the table, the following measurements are
required:
Checkpoint
Voltage
Voltage difference between base (B)
and emitter (E) of amplifier triode
About 0.55 ~ 0.7V
A13
4.5
~
5V
At the same time, check whether the PRE control signal
"#PRE_EN" and AS179 controlled voltage turn normally.
PRE circuit unit