MNC-0000-015
6 of 8
Revision C
Operation Addendum, Block Upconverter
Setup and Turn On
Use this procedure to setup and operate the BUC.
1
Turn ON modem or signal source and set IF input power to -20
dBm ± 3 dB. Verify that the reference frequency is present and
at 2 ± 5 dBm power level.
These power levels are specified at the input of the HPA and must be
adjusted for any cable loss.
The phase noise of the reference frequency and signal source need to
be verified using Figure 1. All spurious signals such as IF and reference
frequency products must be below -60 dBc.
The output frequency accuracy depends on the accuracy of the refer-
ence and IF frequencies. The determining ratios for the frequency
Bands are:
•
Ku Band — (12.8 GHz / Reference Frequency) X Reference
Offset = Output Offset.
•
C Band — (4.90 GHz / Reference Frequency) X Reference
Offset = Output Offset.
•
X Band — (6.95 GHz/Reference Frequency) X Reference
Offset = Output Offset.
Table 1, BUC Output Frequency Plan
Band
LO Freq IF Freq Output Freq
C
4.9
.950
5.85
1.550
6.45
1.750
6.65
X
6.95
0.95
7.9
1.45
8.4
Ku
12.80
.950
13.75
1.700
14.5
13.05
0.95
14.0
1.45
14.5
DBS
16.35
0.95
17.3
1.75
18.1
Notes:
1) RF = IF + LO
2) All frequencies in GHz.
Содержание XTU-400K
Страница 2: ...Document Number MN5 0184 104 Date February 2007 Revision D XTU 400K Operation and Installation Manual...
Страница 10: ...MNC 0000 010 2 of 10 Revision A7...
Страница 22: ...MNC 0100 003 4 Revision C Overview Digital ODU HPAs Figure 1 Typical ODU Antenna Mount Amplifier Block Diagram...
Страница 38: ...Safety Sicherheit MNC 0200 001 14 of 14 Revision E...
Страница 60: ...Unpacking and Installation TWTA Octagon CPU MNC 0300 003 22 of 22 Revision N...
Страница 66: ...MNC 0400 001 6 of 54 Revision G Operation Rack and Digital HPAs...
Страница 90: ...MNC 0400 001 30 of 54 Revision G Operation Rack and Digital HPAs Figure 11 Setup Menu 2...
Страница 97: ...MNC 0400 001 37 of 54 Revision G Operation Rack and Digital HPAs...
Страница 101: ...MNC 0400 001 41 of 54 Revision G Operation Rack and Digital HPAs...
Страница 102: ...MNC 0400 001 42 of 54 Revision G Operation Rack and Digital HPAs Figure 18 Menutree Sheet 1 of 3...
Страница 103: ...MNC 0400 001 43 of 54 Revision G Operation Rack and Digital HPAs Figure 19 Menutree Sheet 2 of 3...
Страница 104: ...MNC 0400 001 44 of 54 Revision G Operation Rack and Digital HPAs Figure 20 Menutree Sheet 3 of 3...
Страница 114: ...MNC 0400 001 54 of 54 Revision G Operation Rack and Digital HPAs...
Страница 120: ...MNC 0500 002 6 of 36 Revision H Amplifier Communication and Protocol Octagon ISA CPU Figure 1 Basic Configuration...
Страница 150: ...MNC 0500 002 36 of 36 Revision H Amplifier Communication and Protocol Octagon ISA CPU...
Страница 162: ...MNC 0700 001 6 Revision F Service and Repair...
Страница 173: ......
Страница 174: ......
Страница 175: ......
Страница 176: ......
Страница 177: ......
Страница 178: ......
Страница 179: ......
Страница 180: ......
Страница 181: ......
Страница 186: ...MNC 0000 015 5 of 8 Revision C Operation Addendum Block Upconverter Figure 3 Detailed BUC Block Diagram...
Страница 189: ...MNC 0000 015 8 of 8 Revision C Operation Addendum Block Upconverter Figure 4 Drift Compensation Block Diagram...