MNC-0000-015
3 of 8
Revision C
Operation Addendum, Block Upconverter
Operation Addendum, Block Upconverter
Overview
The function of the BUC (Block Upconverter) is to convert the
baseband input from a modem at an IF (intermediate frequency) to
the system transmit frequency. The BUC accepts an intermediate
frequency, mixes it with a highly stable LO (local oscillator) and
passes it through a series of circuits that filter and amplify the signal
to produce an output in the desired transmission band. The LO
frequency is derived from the reference frequency that is provided
by the baseband system. The reference frequency is typically 10 or
50 MHz and is critical to the overall system stability and phase
noise. A typical phase noise requirement for a reference source is
shown in Figure 1. The phase noise of the modem input signal at
the IF frequency also affects the system performance and needs to
be 5 to 10 dB below IESS (Intelsat Earth Station Standards) phase
noise profile for optimum performance.
See Figure 1 for a typical block diagram.
Figure 1, Typical Block Diagram of a High Power Amplifier with Block Upconverter.
Note
If the modem being used does not have the IF
multiplexed with the reference, a dixplexer is available
from Xicom (Part Number: 545-0021-001) to combine
the two signals.
Note
Xicom offers SSPA/HPA Block Upconverter options
with an internal 10 MHz reference. For these models,
the Diplexer and 10 MHz crystal are mounted inside
the SSPA/HPA enclosure. The only required input is at
the Intermediate Frequency (IF).
Содержание XTU-400K
Страница 2: ...Document Number MN5 0184 104 Date February 2007 Revision D XTU 400K Operation and Installation Manual...
Страница 10: ...MNC 0000 010 2 of 10 Revision A7...
Страница 22: ...MNC 0100 003 4 Revision C Overview Digital ODU HPAs Figure 1 Typical ODU Antenna Mount Amplifier Block Diagram...
Страница 38: ...Safety Sicherheit MNC 0200 001 14 of 14 Revision E...
Страница 60: ...Unpacking and Installation TWTA Octagon CPU MNC 0300 003 22 of 22 Revision N...
Страница 66: ...MNC 0400 001 6 of 54 Revision G Operation Rack and Digital HPAs...
Страница 90: ...MNC 0400 001 30 of 54 Revision G Operation Rack and Digital HPAs Figure 11 Setup Menu 2...
Страница 97: ...MNC 0400 001 37 of 54 Revision G Operation Rack and Digital HPAs...
Страница 101: ...MNC 0400 001 41 of 54 Revision G Operation Rack and Digital HPAs...
Страница 102: ...MNC 0400 001 42 of 54 Revision G Operation Rack and Digital HPAs Figure 18 Menutree Sheet 1 of 3...
Страница 103: ...MNC 0400 001 43 of 54 Revision G Operation Rack and Digital HPAs Figure 19 Menutree Sheet 2 of 3...
Страница 104: ...MNC 0400 001 44 of 54 Revision G Operation Rack and Digital HPAs Figure 20 Menutree Sheet 3 of 3...
Страница 114: ...MNC 0400 001 54 of 54 Revision G Operation Rack and Digital HPAs...
Страница 120: ...MNC 0500 002 6 of 36 Revision H Amplifier Communication and Protocol Octagon ISA CPU Figure 1 Basic Configuration...
Страница 150: ...MNC 0500 002 36 of 36 Revision H Amplifier Communication and Protocol Octagon ISA CPU...
Страница 162: ...MNC 0700 001 6 Revision F Service and Repair...
Страница 173: ......
Страница 174: ......
Страница 175: ......
Страница 176: ......
Страница 177: ......
Страница 178: ......
Страница 179: ......
Страница 180: ......
Страница 181: ......
Страница 186: ...MNC 0000 015 5 of 8 Revision C Operation Addendum Block Upconverter Figure 3 Detailed BUC Block Diagram...
Страница 189: ...MNC 0000 015 8 of 8 Revision C Operation Addendum Block Upconverter Figure 4 Drift Compensation Block Diagram...