FusionServer G5500 V6 Server
Technical White Paper
5 Hardware Description
2023-02-14
42
Drive number
Drive Number Displayed
on the iBMC WebUI
Drive Number Identified
by the RAID Controller
Card
20
20
20
21
21
21
22
a
22
22
23
a
23
23
⚫
a: SAS/SATA/NVMe drives are supported.
5.5.2 Drive Indicators
SAS/SATA Drive Indicators
Figure 5-15
SAS/SATA drive indicators
Table 5-11
SAS/SATA drive indicators
Active Indicator
(Green)
Fault Indicator
(Red/Blue)
Description
Off
Off
The drive is not detected.
Steady on
Off
The drive is detected.
Blinking at 4 Hz
Off
Data is being read or written properly, or
data on the primary drive is being rebuilt.
Steady on
Blinking blue at 4
Hz
The drive is being located.
Blinking at 1 Hz
Blinking red at 1
Hz synchronously
Data on the secondary drive is being
rebuilt.
Off
Red steady on
A drive in a RAID array is removed.
Steady on
Red steady on
The drive is faulty.