![xFusion Digital Technologies FusionServer G5500 V6 Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/xfusion-digital-technologies/fusionserver-g5500-v6/fusionserver-g5500-v6_manual_3327721010.webp)
FusionServer G5500 V6 Server
Technical White Paper
2 Product Features
2023-02-14
10
⚫
Configuring any network port on the OCP 3.0 network adapter or PCIe NIC (with NC-SI
enabled).
⚫
Enabling, disabling, and setting a virtual local area network (VLAN) ID for this port. The VLAN
ID is
0
and disabled by default.
⚫
Configuring IPv4 addresses (IPv4 address, subnet mask, and default gateway) and IPv6
addresses (IPv6 address, prefix length) for this port.
⚫
The integrated Unified Extensible Firmware Interface (UEFI) improves setup,
configuration, and update efficiency and simplifies fault clearance.
⚫
The lockable server chassis panel ensures local data security.
⚫
Chassis cover opening detection is supported to enhance physical security.
⚫
Intel Execute Disable Bit (EDB) function prevents certain types of malicious buffer
overflow attacks when working with a supported OS.
⚫
Intel
®
Trusted Execution Technology prevents malicious software attacks based
on hardware, prevents the firmware on the device from being maliciously
modified, and prevents unauthorized boot block execution.
⚫
Intel
®
Software Guard Extensions (Intel
®
SGX) technology allows applications to
run in their own independent space without being affected by other software
running in the system, thereby enhancing security.
⚫
The secure boot based on the chip RoT implements level-by-level firmware
verification starting from the hardware RoT and builds a complete secure boot
chain.
⚫
The trusted platform module (TPM) provides advanced encryption functions,
such as digital signatures and remote authentication.
⚫
The following requirements in NIST SP 800-147B are met:
−
The BIOS firmware digital signature update mechanism is supported. During
the upgrade, the digital signature is verified to prevent unauthorized BIOS
firmware upgrade.
−
The flash security protection mechanism is supported to prevent
unauthorized modification of the flash memory in the OS.
Energy Efficiency
⚫
The server supports 80 PLUS Platinum/Titanium PSUs of different energy
efficiency levels. The PSU efficiency reaches 96% at 50% load.
⚫
Active/standby power supply and HVDC power supply are supported, improving
the efficiency of the power supply system.
⚫
Efficient voltage regulator-down (VRD) power supplies for boards minimize the
energy loss from DC-to-DC power conversion.
⚫
Area-based, Proportional-Integral-Derivative (PID) intelligent fan speed
adjustment and intelligent CPU frequency scaling optimize heat dissipation and
reduce overall system power consumption.
⚫
The improved thermal design with energy-efficient fans ensures optimal heat
dissipation and reduces system power consumption.
⚫
The server is protected with power capping and power control measures.
⚫
Staggered spinup of drives reduces the server boot power consumption.