background image

FusionServer 2288 V5 Server 
Technical White Paper 

C Acronyms and Abbreviations 

 

2022-11-11 

85 

 

REACH 

Registration Evaluation and Authorization of Chemicals 

RJ45 

registered jack 45 

RoHS 

Restriction of the Use of Certain Hazardous Substances in 
Electrical and Electronic Equipment 

 

SAS 

Serial Attached Small Computer System Interface 

SATA 

Serial Advanced Technology Attachment 

SCM 

supply chain management 

SDDC 

single device data correction 

SERDES 

serializer/deserializer 

SGMII 

serial gigabit media independent interface 

SMI 

serial management interface 

SMTP 

Simple Mail Transfer Protocol 

SNMP 

Simple Network Management Protocol 

SOL 

serial over LAN 

SONCAP 

Standards Organization of Nigeria-Conformity Assessment 
Program 

SSD 

solid-state drive 

SSE 

Streaming SIMD Extensions 

 

TACH 

tachometer signal 

TBT 

Turbo Boost Technology 

TCG 

Trusted Computing Group 

TCM 

trusted cryptography module 

TCO 

total cost of ownership 

TDP 

thermal design power 

TELNET 

Telecommunication Network Protocol 

TET 

Trusted Execution Technology 

TFM 

TransFlash module 

Содержание FusionServer 2288 V5

Страница 1: ...FusionServer 2288 V5 Server Technical White Paper Issue 04 Date 2022 11 11 xFusion Digital Technologies Co Ltd ...

Страница 2: ...t bear any liability resulting from the use of xFusion The purchased products services and features are stipulated by the contract made between xFusion and the customer All or part of the products services and features described in this document may not be within the purchase scope or the usage scope Unless otherwise specified in the contract all statements information and recommendations in this ...

Страница 3: ...Panel 20 5 2 1 Appearance 20 5 2 2 Indicators 21 5 2 3 Ports 22 5 3 Processor 23 5 4 Memory 24 5 4 1 DDR4 Memory 24 5 4 1 1 Memory Identifier 24 5 4 1 2 Memory Subsystem Architecture 25 5 4 1 3 Memory Compatibility 26 5 4 1 4 DIMM Installation Rules 28 5 4 1 5 Memory Installation Positions 28 5 4 1 6 Memory Protection Technologies 30 5 5 Storage 31 5 5 1 Drive Configurations 31 5 5 2 Drive Numberi...

Страница 4: ...45 5 10 Boards 46 5 10 1 Mainboard 46 5 10 2 Drive Backplane 47 6 Product Specifications 50 6 1 Technical Specifications 50 6 2 Environmental Specifications 53 6 3 Physical Specifications 55 7 Software and Hardware Compatibility 58 8 Safety Instructions 59 8 1 Security 59 8 2 Maintenance and Warranty 62 9 System Management 63 A Appendix 65 B Glossary 78 C Acronyms and Abbreviations 81 ...

Страница 5: ...vel of risk which if not avoided will result in death or serious injury Indicates a hazard with a medium level of risk which if not avoided could result in death or serious injury Indicates a hazard with a low level of risk which if not avoided could result in minor or moderate injury Indicates a potentially hazardous situation which if not avoided could result in equipment damage data loss perfor...

Страница 6: ...tory Issue Date Description 04 2022 11 11 Updated 6 3 Physical Specifications Updated 8 1 Security 03 2022 08 12 Optimized 6 3 Physical Specifications 02 2022 06 25 Added a figure that shows how to measure dimensions Added A 1 Chassis Label 01 2021 12 20 This issue is the first official release ...

Страница 7: ...ing enterprise and telecom applications The 2288 V5 is ideal for IT core services cloud computing high performance computing distributed storage big data processing enterprise or telecom applications and other complex workloads The reliable 2288 V5 features low power consumption high scalability easy deployment and simplified management For details about the 2288 V5 nameplate information see A 4 N...

Страница 8: ...etter use hardware to address virtualization workloads Intel Advanced Vector Extensions 512 Intel AVX 512 significantly accelerates floating point performance for computing intensive applications The Cascade Lake processors support Intel Deep Learning Boost vector neural network instructions VNNI to improve the performance of deep learning applications The server supports double data rate 4 DDR4 r...

Страница 9: ... security The Network Controller Sideband Interface NC SI allows a network port to serve as a management port and a service port for maximized return on investment ROI for customers The NC SI feature is disabled by default and can be enabled through the iBMC or BIOS The integrated Unified Extensible Firmware Interface UEFI improves setup configuration and update efficiency and simplifies fault han...

Страница 10: ...ed adjustment and intelligent CPU frequency scaling optimize heat dissipation and reduce overall system power consumption The improved thermal design with energy efficient fans ensures optimal heat dissipation and reduces system power consumption The server is protected with power capping and power control measures Staggered spin up for drives reduces the server boot power consumption Intel Intell...

Страница 11: ...al structure of a 2288 V5 with 12 x 3 5 drives example 1 I O module 1 2 I O module 2 3 PSUs 4 Filler panel 5 Chassis 6 Supercapacitor holder 7 Air duct 8 Front drive backplane 9 Fan module brackets 10 Fan modules 11 Front drives 12 FlexIO card 13 Mainboard 14 Screw in RAID controller card 15 Trusted platform module 16 DIMMs ...

Страница 12: ...FusionServer 2288 V5 Server Technical White Paper 3 Physical Structure 2022 11 11 12 TPM 17 Processors 18 Heat sinks ...

Страница 13: ... Two PCIe riser cards connect to the processors through PCIe buses to provide ease of expandability and connection The RAID controller card on the mainboard connects to CPU 1 through PCIe buses and connects to the drive backplane through SAS signal cables A variety of drive backplanes are provided to support different local storage configurations The LBG 2 Platform Controller Hub PCH supports two ...

Страница 14: ...14 5 Hardware Description 5 1 Front Panel 5 2 Rear Panel 5 3 Processor 5 4 Memory 5 5 Storage 5 6 Network 5 7 I O Expansion 5 8 PSUs 5 9 Fans 5 10 Boards 5 1 Front Panel 5 1 1 Appearance 8 x 2 5 drive configuration Figure 5 1 Front view 1 Drives 2 Slide out label plate with an SN label ...

Страница 15: ...12 x 3 5 drive configuration Figure 5 2 Front view 1 Drives 2 Slide out label plate with an SN label 25 x 2 5 drive configuration Figure 5 3 Front view 1 Drives 2 Slide out label plate with an SN label 5 1 2 Indicators and Buttons Indicator and Button Positions 8 x 2 5 drive configuration ...

Страница 16: ...n status indicator 4 Fault diagnostic LED 5 Health status indicator 6 UID Button Indicator 7 Power button indicator 12 x 3 5 drive configuration Figure 5 5 Indicators and buttons on the front panel 1 10GE LOM port connection status indicator NOTE The 10GE indicator is unavailable 2 GE LOM port 1 connection status indicator 3 GE LOM port 2 connection status indicator 4 Fault diagnostic LED 5 Health...

Страница 17: ... Silkscreen Indicator Butt on Description Fault diagnostic LED The device is operating properly Error code A component is faulty For details about error codes see the FusionServer Rack Server iBMC Alarm Handling Power button indicator Power indicator Off The device is not powered on Steady green The device is powered on Blinking yellow The iBMC is starting The power button is locked and cannot be ...

Страница 18: ...old down this button for 4 to 6 seconds to reset the iBMC Health status indicator Off The device is powered off or is faulty Blinking red at 1 Hz A major alarm has been generated on the system Blinking red at 5 Hz A critical alarm has been generated on the system Steady green The device is operating properly LOM port connection status indicator Each indicator shows the connection status of an Ethe...

Страница 19: ... configuration Figure 5 8 Ports on the front panel 1 USB 2 0 ports 25 x 2 5 drive configuration Figure 5 9 Ports on the front panel 1 USB 2 0 ports Port Description Table 5 2 Ports on the front panel Port Type Quantity Description USB port USB 2 0 2 Used to connect to a USB device NOTICE Before connecting an external USB device check that the USB device ...

Страница 20: ...ly The server may operate abnormally if an abnormal USB device is connected 5 2 Rear Panel 5 2 1 Appearance Figure 5 10 Rear view 1 I O module 1 2 I O module 2 3 Filler panel 4 PSU 2 5 PSU 1 6 Optional FlexIO card I O modules 1 and 2 can be configured with drive modules or PCIe riser modules The preceding figure is for reference only ...

Страница 21: ...nel Indicator Description LOM port indicator For details see 5 6 1 LOMs PSU Indicator Off No power is supplied Blinking green at 1 Hz The input is normal and the server is standby The input is overvoltage or undervoltage The PSU is in deep hibernation mode Blinking green at 4 Hz The firmware is being upgraded online Steady green The power input and output are normal Steady orange The input is norm...

Страница 22: ...tely running a command on the iBMC CLI Management network port data transmission status indicator Off No data is being transmitted Blinking yellow Data is being transmitted Management network port connection status indicator Off The network port is not connected Steady green The network port is properly connected 5 2 3 Ports Port Positions Figure 5 12 Ports on the rear panel 1 VGA port 2 LOM port ...

Страница 23: ...SB 3 0 2 Used to connect to a USB device NOTICE Before connecting an external USB device check that the USB device functions properly The server may operate abnormally if an abnormal USB device is connected PSU socket 2 Used to connect to the power distribution unit PDU in the cabinet You can select the number of power supply units PSUs as required NOTE When determining the quantity of PSUs ensure...

Страница 24: ... 5 Hardware Description 2022 11 11 24 Figure 5 13 Processor positions 5 4 Memory 5 4 1 DDR4 Memory 5 4 1 1 Memory Identifier You can determine the memory module properties based on the label attached to the memory module Figure 5 14 Memory identifier ...

Страница 25: ...mum memory speed 2133 MT S 2400 MT S 2666 MT S 2933 MT S 3200 MT S 6 Column Access Strobe CAS latency P 15 T 17 7 DIMM type R RDIMM L LRDIMM 5 4 1 2 Memory Subsystem Architecture The 2288 V5 provides 16 memory slots Each processor integrates six memory channels Install the memory modules in the primary memory channels first If the primary memory channel is not populated the memory modules in secon...

Страница 26: ...by a processor Maximum operating speed of a DIMM The DDR4 DIMMs of different types RDIMM and LRDIMM and specifications capacity bit width rank and height cannot be used together Contact your local sales representative or use the Compatibility Checker to determine the components to be used The memory can be used with Intel Xeon Scalable Skylake and Cascade Lake processors The maximum memory capacit...

Страница 27: ...ns Maximum capacity per DDR4 DIMM GB 16 32 64 Rated speed MT s 2933 2933 2666 Rank Single rank Dual rank Quad rank Operating voltage V 1 2 1 2 1 2 Maximum number of DDR4 DIMMs in a servera 16 16 16 Maximum DDR4 memory capacity of the server GB b 256 512 1024 Maximum operating speed MT s 1DPCc 2933d 2933d 2666 2DPC 2666 2666 2666 a The maximum number of DDR4 memory modules is based on dual processo...

Страница 28: ... configurations Each populated channel must have a spare rank Memory mirroring mode Comply with the general installation guidelines Each processor supports two integrated memory controllers IMCs At least two channels of each IMC are used for installing memory modules channels 1 and 2 or channels 1 2 and 3 The installed memory modules must be identical in size and organization For a multi processor...

Страница 29: ...FusionServer 2288 V5 Server Technical White Paper 5 Hardware Description 2022 11 11 29 Figure 5 15 Memory slots Figure 5 16 DDR4 memory installation guidelines 1 processor ...

Страница 30: ...ction Technologies The following memory protection technologies are supported ECC Full mirroring Address range mirroring SDDC SDDC 1 Rank sparing mode Static virtual lockstep Faulty DIMM isolation Memory thermal throttling Memory address parity protection Memory demand patrol scrubbing Device tagging Data scrambling Adaptive double device data correction ADDDC ADDDC 1 ...

Страница 31: ...ots 40 and 41 support only SAS SATA drives I O module 2 2 x 3 5 Slots 42 and 43 support only SAS SATA drives 1 x RAID controller card Screw in RAID controller card installed in the RAID controller card connector on the mainboard 25 x 2 5 drive EXP configurationa Front drives 25 x 2 5 Slots 0 to 24 support only SAS SATA drives I O module 1 2 x 3 5 Slots 40 and 41 support only SAS SATA drives 1 x RA...

Страница 32: ...ver Technical White Paper 5 Hardware Description 2022 11 11 32 5 5 2 Drive Numbering 8 x 2 5 drive configuration Figure 5 18 Drive numbering 12 x 3 5 drive configuration Figure 5 19 Drive numbering 25 x 2 5 drive configuration ...

Страница 33: ...y Indicator Green Fault Indicator Yellow Description Off Off The drive is not in position Steady on Off The drive is detected Blinking at 4 Hz Off Data is being read or written normally or data on the primary drive is being rebuilt Steady on Blinking at 1 Hz The drive is being located Blinking at 1 Hz Blinking at 1 Hz Data on the secondary drive is being rebuilt Off Steady on A member drive in the...

Страница 34: ...not detected M 2 FRU activity indicator Off The M 2 FRU is not in position or is faulty Blinking green Data is being read written or synchronized Steady green The M 2 FRU is inactive 5 5 4 RAID Controller Card The RAID controller card supports RAID configuration RAID level migration and drive roaming Contact your local sales representative or use the Compatibility Checker to determine the componen...

Страница 35: ... LOM ports The LOM ports support NC SI WOL and PXE The LOM ports do not support forced rates The electrical LOM ports cannot be connected to power over Ethernet PoE devices such as a switch with PoE enabled Connecting a LOM port to a PoE device may cause link communication failure or even damage the NIC The electrical LOM ports GE electrical ports do not support SR IOV Forcibly powering off a serv...

Страница 36: ...g transmitted Blinking yellow Data is being transmitted 5 6 2 FlexIO Cards FlexIO cards provide network expansion capabilities The FlexIO card with electrical ports cannot be connected to power over Ethernet PoE devices such as a switch with PoE enabled Otherwise link communication failure or even damage to the FlexIO card may be caused Contact your local sales representative or use the Compatibil...

Страница 37: ...4 SM211 i350 GE electrical port 2 SM212 i350 GE electrical port 4 SM233 X540 10GE electrical port 2 SM251 CX3 56G IB optical port 2 SM252 CX3 56G IB optical port 1 Indicator Positions SM210 SM212 with four GE electrical ports Figure 5 25 SM210 SM212 network port indicators SM211 with two GE electrical ports Figure 5 26 SM211 network port indicators SM233 with two 10GE electrical ports ...

Страница 38: ...on GE electrical port Data transmission status indicator Off No data is being transmitted Blinking yellow Data is being transmitted Connection status indicator Off The network port is not connected Steady green The network port is properly connected 10GE electrical port Transmission rate indicator Off The data transmission rate is 10 100 Mbit s Steady green The data transmission rate is 10 Gbit s ...

Страница 39: ...ogical link is normal but no data is being transmitted 5 7 I O Expansion 5 7 1 PCIe Cards PCIe cards provide ease of expandability and connection The electrical ports provided by PCIe NICs cannot be connected to power over Ethernet PoE devices such as a switch with PoE enabled Connecting such an electrical port to a PoE device may cause link communication failure or even damage the NIC Contact you...

Страница 40: ...o 6 If a dual slot PCIe riser module is used slot 5 is unavailable PCIe Riser Modules PCIe riser module 1 universal Provides PCIe slots 1 and 3 when installed in I O module 1 Provides PCIe slots 4 and 6 when installed in I O module 2 Figure 5 31 PCIe riser module 1 PCIe riser module 2 universal Provides PCIe slots 1 2 and 3 when installed in I O module 1 Provides PCIe slots 4 5 and 6 when installe...

Страница 41: ...te Paper 5 Hardware Description 2022 11 11 41 Figure 5 32 PCIe riser module 2 PCIe riser module 3 for PCIe SSD cards only Provides PCIe slots 1 2 and 3 when installed in I O module 1 Provides PCIe slots 4 5 and 6 when installed in I O module 2 ...

Страница 42: ...CPU socket are unavailable Table 5 14 PCIe slot description PCIe Slot CPU PCIe Standa rds Conne ctor Width Bus Width Port No Root Port B D F Device B D F Slot Size RAID controll er card CPU 1 PCIe 3 0 x8 x8 Port1C 17 02 0 1D 00 0 LOM CPU 1 PCIe 3 0 x8 x8 Port1A 17 00 0 1A 00 0 FlexIO card CPU 2 PCIe 3 0 x8 x8 Port2A AE 00 0 AF 00 0 Slot 1 CPU 1 PCIe x16 2 sl Port2A 3A 00 3B 00 FHFL ...

Страница 43: ...Slot Size 3 0 ot PCI e riser mod ule PR M x16 3 sl ot PR M x8 0 0 Slot 2 CPU 1 PCIe 3 0 x16 2 sl ot PR M N A 3 sl ot PR M x8 Port2C 3A 02 0 3E 00 0 FHFL Slot 3 CPU 1 PCIe 3 0 x16 x8 Port3A 5D 00 0 5E 00 0 FHHL Slot 4 CPU 2 PCIe 3 0 x16 2 sl ot PR M x16 3 sl ot PR M x8 Port1A 85 00 0 86 00 0 FHFL Slot 5 CPU 2 PCIe 3 0 x16 2 sl ot PR M N A 3 sl ot PR M x8 Port1C 85 02 0 89 00 0 FHFL ...

Страница 44: ...e slots are backward compatible with full height half length and half height half length PCIe cards Full height half length PCIe slots are backward compatible with half height half length PCIe cards All slots support PCIe cards of up to 75 W The power of a PCIe card varies depending on its model 5 8 PSUs The server supports one or two PSUs The server supports AC or DC PSUs The PSUs are hot swappab...

Страница 45: ... 11 11 45 Figure 5 34 PSU positions 5 9 Fans The server supports four fan modules The fan modules are hot swappable The server tolerates failure of a single fan The fan speed can be adjusted The same model of fan modules must be used in a server Figure 5 35 Fan module positions ...

Страница 46: ...2288 V5 mainboard 1 USB 3 0 port USB 3 0 CONN USB1 2 UID indicator LED24 3 Serial port J47 4 Management network port 5 GE electrical port 6 GE electrical port 7 VGA connector VGA CONN VGA3 8 PCIe riser 1 slot PCIe1 and PCIe5 corresponding to CPU 1 9 Rear drive backplane power connector 2 REAR BP 10 NC SI connector NCSI CONN J49 ...

Страница 47: ...U4042 25 Drive backplane power connector HDD BP PWR2 J23 26 Rear drive backplane power connector 3 REAR BP PWR3 J27 27 Rear 4 x 2 5 inch drive backplane low speed signal connector REAR 4 2 5 HDD BP J21 28 PSU 2 connector J18 29 PSU 1 connector J17 30 Left mounting ear connector LCIC BOARD J39 31 DIP switch SW1 SW2 b 32 I O NIC connectors IO BOARD J35 J29 33 RAID controller card connector RAID CARD...

Страница 48: ...AS HD connector PORT A J28 4 Power connector J24 12 x 3 5 drive EXP backplane Figure 5 38 12 x 3 5 drive EXP backplane BOM 03024MSG and 03029JSA 1 Indicator signal cable connector J32 2 mini SAS HD connector PORT A J28 3 mini SAS HD connector PORT B J29 4 mini SAS HD connector REAR PORT J31 5 Backplane signal cable connector J1 6 Power connector J24 7 Indicator signal cable connector J35 25 x 2 5 ...

Страница 49: ...ini SAS HD connector PORT A J28 3 mini SAS HD connector PORT B J29 4 mini SAS HD connector REAR PORT J31 5 Backplane signal cable connector J1 6 Power connector J24 7 Indicator signal cable connector J35 Rear Drive Backplane 2 x 3 5 drive backplane Figure 5 40 2 x 3 5 drive backplane BOM 03022HYE 1 mini SAS HD connector J3 2 Indicator signal cable connector J24 3 Power connector J1 ...

Страница 50: ... Intel Xeon Scalable Skylake and Cascade Lake processors Built in memory controller and six memory channels Built in PCIe controller supporting PCIe 3 0 and 48 lanes per processor Two UPI buses between processors providing up to 10 4GT s transmission per channel Up to 20 cores per processor Max 3 8 GHz Min 1 375 MB L3 cache per core Max 125 W TDP NOTE The preceding information is for reference onl...

Страница 51: ...ll capacity M 2 SSD is used as the boot device a dedicated log drive or log server is required for logging For example you can dump VMware logs in either of the following ways Redirect scratch For details see https kb vmware com s article 1033696 Configure syslog For details see https kb vmware com s article 2003322 The M 2 SSD cannot be used to store data due to poor endurance In write intensive ...

Страница 52: ...evices such as a switch with PoE enabled Connecting such an electrical port to a PoE device may cause link communication failure or even damage the NIC Forcibly powering off a server will cause intermittent NC SI disconnection and disable the WOL function of the LOM ports To restore the NC SI connection refresh the iBMC WebUI I O expansion 8 PCIe 3 0 slots One slot dedicated for a screw in RAID co...

Страница 53: ...s that are in secure boot mode The integrated video card can provide the maximum display resolution 1920 x 1200 only after the video card driver matching the operating system version is installed Otherwise only the default resolution supported by the operating system is provided System management Supports UEFI Supports iBMC Supports NC SI Supports integration with third party management systems Se...

Страница 54: ... 25 ft When the configuration complies with ASHRAE Class A3 standards and the altitude is above 900 m 2952 76 ft the highest operating temperature decreases by 1 C 1 8 F for every increase of 175 m 574 14 ft HDDs cannot be used at an altitude of over 3050 m 10006 44 ft Corrosive gaseous contaminant Maximum corrosion product thickness growth rate Copper corrosion rate test 300 Å month meeting level...

Страница 55: ...d in the preceding table the following preservation time is recommended Maximum preservation duration of SSDs 12 months in power off state without data stored 3 months in power off state with data stored Maximum preservation duration of HDDs 6 months in unpacked packed and powered off state The maximum preservation duration is determined according to the preservation specifications provided by dri...

Страница 56: ...rails apply only to our company s cabinets Static rail kit applies to cabinets with a distance of 543 5 mm to 848 5 mm 21 40 in to 33 41 in between the front and rear mounting bars Ball bearing rail kit applies to cabinets with a distance of 610 mm to 914 mm 24 02 in to 35 98 in between the front and rear mounting bars Fully equipped weight Net weight Maximum weight for server with 8 x 2 5 front d...

Страница 57: ...FusionServer 2288 V5 Server Technical White Paper 6 Product Specifications 2022 11 11 57 Item Description information ...

Страница 58: ...ic middleware software and hardware The slight differences of the application software middleware basic software and hardware may cause performance inconsistency between the application layer and test software layer If the customer has requirements on the performance of specific application software contact sales personnel to apply for POC tests in the pre sales phase to determine detailed softwar...

Страница 59: ...orming high voltage operations and driving a forklift If this device works in a residential environment the wireless interference may be generated Human Safety This equipment is not suitable for use in places where children may be present Only certified or authorized personnel are allowed to install the device Discontinue any dangerous operations and take protective measures Report anything that c...

Страница 60: ...tches and jewelry Figure 8 2 shows conductive objects that must be removed before you touch a device Figure 8 2 Removing conductive objects Figure 8 3 shows how to wear an ESD wrist strap a Put your hands into the ESD wrist strap b Tighten the strap buckle and ensure that the ESD wrist strap is in contact with your skin c Insert the ground terminal attached to the ESD wrist strap into the jack on ...

Страница 61: ...ipment Safety Use the recommended power cables at all times Use power cables only for dedicated servers Do not use them for other devices Before operating equipment wear ESD clothes and gloves to prevent electrostatic sensitive devices from being damaged by ESD When moving a device hold the bottom of the device Do not hold the handles of the installed modules such as the PSUs fan modules drives an...

Страница 62: ...rried by a Person To reduce the risk of personal injury comply with local regulations with regard to the maximum weight one person is permitted to carry Table 8 1 lists the maximum weight one person is permitted to carry as stipulated by a number of organizations Table 8 1 Maximum weight carried per person Organization Weight kg lb European Committee for Standardization CEN 25 55 13 International ...

Страница 63: ...s and protocols KVM and text console redirection Remote virtual media IPMI SNMP Common information model CIM Redfish Browser based login Specifications Table 9 1 iBMC specifications Specifications Description Management interface Integrates with any standard management system through the following interfaces IPMI CLI HTTPS SNMP Redfish Fault Detection Detects and accurately locates faults in a fie...

Страница 64: ...eproduction Reproduces faults to facilitate fault diagnosis Screen snapshots and videos Allows users to view screenshots and videos without login facilitating routine preventive maintenance inspection PMI Black Box Allows users to enable or disable the black box function and download black box data DNS LDAP Supports domain management and directory services which significantly simplify network and ...

Страница 65: ...on are for reference only For details see the actual product A 1 1 On the Front Top Figure A 1 Chassis head label 1 Nameplate 2 Certificate 3 Quick access tag 4 SN NOTE For details see A 2 Product SN 5 Reserved space for custom label 6 Pressure proof label NOTE This label indicates that do not place any objects on top of a rack mounted ...

Страница 66: ...vice A 1 1 1 Nameplate Figure A 2 Nameplate example Table A 1 Nameplate description No Description 1 Server Model For details see A 4 Nameplate 2 Device names 3 Power Supply Requirements 4 Vendor Information 5 Authentication ID A 1 1 2 Certificate Figure A 3 Sample certificate ...

Страница 67: ... is Z which is fixed 3 Y indicates a server B indicates a semi finished server N indicates a spare part 4 The value is 0 This digit is a reserved digit 5 Indicates the year two digits 6 Indicates the month one digit Digits 1 to 9 indicate January to September respectively Letters A to C indicate October to December respectively 7 Indicates the day one digit Digits 1 to 9 indicate the 1st to 9th Le...

Страница 68: ...icates the manufacturing serial number five digits A 1 1 3 Sample Quick Access Tags Figure A 5 Sample quick access tags Table A 4 Quick access tab description No Description 1 IP address of the iBMC management network port 2 Subnet mask of the iBMC management network port 3 Default iBMC user name 4 Default iBMC password 5 Default BIOS password 6 Technical support website 7 P N Code 8 QR Code NOTE ...

Страница 69: ...guide is located on the inside of the chassis cover It describes how to remove the mainboard components important components of the chassis precautions and QR codes of technical resources The pictures are for reference only For details see the actual product The quick guide is optional For details see the actual product A 2 Product SN The serial number SN on the slide out label plate uniquely iden...

Страница 70: ...tively Letters P to Y indicate years 2023 to 2032 respectively NOTE The years from 2010 are represented by upper case letters excluding I O and Z because the three letters are similar to the digits 1 0 and 2 The second character indicates the month Digits 1 to 9 indicate January to September respectively Letters A to C indicate October to December respectively 5 Serial number six digits 6 RoHS com...

Страница 71: ...IB standard cards If a single fan is faulty the maximum operating temperature is 5 C 9 F lower than the rated value A 4 Nameplate Certified Model Usage Restrictions H22M 05 Global A 5 RAS Features The server supports a variety of Reliability Availability and Serviceability RAS features You can configure these features for better performance For details about how to configure these features see the...

Страница 72: ... error probability and improve memory data flow reliability and address error detection PCIe PCIe Advanced Error Reporting Provides a PCIe advanced error reporting mechanism to improve server serviceability UPI Intel UPI Link Level Retry Provides a retry mechanism to improve the reliability of UPI links Intel UPI Protocol Protection via CRC Provides cyclic redundancy check CRC protection for UPI d...

Страница 73: ...nd improve system serviceability BIOS Abstraction Layer for Error Handling The BIOS processes errors and reports error information to the OS based on specifications improving system serviceability BIOS based Predictive Failure Analysis PFA The OS takes the lead The BIOS provides information about physical memory error units The OS tracks predicts and handles the errors A 6 Sensor List Sensor Descr...

Страница 74: ...indicates the CPU number The value is 1 or 2 CPUN DDR VDDQ 1 2 V DIMM voltage Mainboard N indicates the CPU number The value is 1 or 2 CPUN DDR VDDQ2 1 2 V DIMM voltage Mainboard N indicates the CPU number The value is 1 or 2 CPUN VSA CPU VSA voltage Mainboard N indicates the CPU number The value is 1 or 2 CPUN VCCIO CPU VCCIO voltage Mainboard N indicates the CPU number The value is 1 or 2 CPUN V...

Страница 75: ...N QPI Link CPU QPI link fault diagnosis health status Mainboard or CPUN N indicates the CPU number The value is 1 or 2 CPUN Prochot CPU Prochot CPUN N indicates the CPU number The value is 1 or 2 CPUN Status CPU status CPUN N indicates the CPU number The value is 1 or 2 CPUN Memory DIMM status CPUN N indicates the CPU number The value is 1 or 2 FANN Status Fan status Fan module N N indicates the f...

Страница 76: ...ard N N indicates the riser card slot number The value ranges from 1 to 3 SAS Cable Entity presence SAS cable FANN Presence Fan presence Fan module N N indicates the fan module number The value ranges from 1 to 4 FANN R Presence RAID Presence RAID controller card presence RAID controller card LCD Status LCD health status LCD LCD Presence LCD presence LCD PS Redundancy Redundancy failure due to PSU...

Страница 77: ...the RAID controller card PCIe RAID controller card RAID Temp RAID controller card temperature RAID controller card RAID Status RAID controller card health status RAID controller card RAID PCIE ERR RAID controller card fault diagnosis health status RAID controller card IB TEMP IB adapter temperature IB card PCIe OP Temp PCIe card optical module temperature PCIe card PCIe NIC Temp PCIe card chip tem...

Страница 78: ...Intel and DEC Ethernet uses the Carrier Sense Multiple Access Collision Detection CSMA CD access method and allows data transfer over various cables at 10 Mbit s The Ethernet specification is the basis for the IEEE 802 3 standard B 2 F J G Gigabit Ethernet GE An extension and enhancement of traditional shared media Ethernet standards It is compatible with 10M and 100M Ethernet and complies with IE...

Страница 79: ...system Intel is the main sponsor for PCIe PCIe is used only for internal interconnection A PCI system can be transformed to a PCIe one by modifying the physical layer instead of software PCIe delivers a faster speed and can replace almost all AGP and PCI buses R redundancy A mechanism that allows a backup device to automatically take over services from a faulty device to ensure uninterrupted runni...

Страница 80: ... Glossary 2022 11 11 80 B 5 U Z U U A unit defined in International Electrotechnical Commission IEC 60297 1 to measure the height of a cabinet or chassis 1 U 44 45 mm UltraPath Interconnect UPI A point to point processor interconnect developed by Intel ...

Страница 81: ...rnating current AES Advanced Encryption Standard New Instruction Set ARP Address Resolution Protocol AVX Advanced Vector Extensions B BBU backup battery unit BIOS Basic Input Output System C CD calendar day CE Conformite Europeenne CIM Common Information Model CLI command line interface D DC direct current DCPMM DC persistent memory module ...

Страница 82: ...ss memory DVD digital video disc E ECC error checking and correcting ECMA European Computer Manufacturer Association EDB Execute Disable Bit EN European Efficiency ERP enterprise resource planning ETS European Telecommunication Standards C 2 F J F FB DIMM Fully Buffered DIMM FC Fiber Channel FCC Federal Communications Commission FCoE Fibre Channel over Ethernet FTP File Transfer Protocol G GE Giga...

Страница 83: ...MP Internet Control Message Protocol IDC Internet Data Center IEC International Electrotechnical Commission IEEE Institute of Electrical and Electronics Engineers IGMP Internet Group Message Protocol IOPS input output operations per second IP Internet Protocol IPC intelligent power capability IPMB Intelligent Platform Management Bus IPMI Intelligent Platform Management Interface C 3 K O K KVM keyb...

Страница 84: ...Network Controller Sideband Interface C 4 P T P PCIe Peripheral Component Interconnect Express PDU power distribution unit PHY physical layer PMBUS power management bus POK power OK PWM pulse width modulation PXE Preboot Execution Environment Q QPI Quick Path Interconnect R RAID redundant array of independent disks RAS reliability availability and serviceability RDIMM registered dual in line memor...

Страница 85: ... device data correction SERDES serializer deserializer SGMII serial gigabit media independent interface SMI serial management interface SMTP Simple Mail Transfer Protocol SNMP Simple Network Management Protocol SOL serial over LAN SONCAP Standards Organization of Nigeria Conformity Assessment Program SSD solid state drive SSE Streaming SIMD Extensions T TACH tachometer signal TBT Turbo Boost Techn...

Страница 86: ...d dual in line memory module UEFI Unified Extensible Firmware Interface UID unit identification light UL Underwriter Laboratories Inc USB Universal Serial Bus V VCCI Voluntary Control Council for Interference by Information Technology Equipment VGA Video Graphics Array VLAN virtual local area network VRD voltage regulator down W WEEE waste electrical and electronic equipment WSMAN Web Service Mana...

Отзывы: