FusionServer 2288 V5 Server
Technical White Paper
A Appendix
2022-11-11
71
Configuration Max. 35°C (95°F)
Max. 40°C (104°F)
⚫
Rear drives
⚫
PCIe SSD cards
12 x 3.5" drive
EXP
configuration
⚫
All options supported
Options not supported:
⚫
Platinum 8156 and Gold
5122/5120T/6128/6138T/6130
T/6126T processors
⚫
Rear drives
⚫
PCIe SSD cards
⚫
IB cards
25 x 2.5" drive
EXP
configuration
⚫
All options supported
Options not supported:
⚫
Platinum 8156 and Gold
5122/5120T/6128/6138T/6130
T/6126T processors
⚫
Rear drives
⚫
PCIe SSD cards
⚫
IB standard cards
If a single fan is faulty, the maximum operating temperature is 5°C (9°F) lower than the rated value.
A.4 Nameplate
Certified Model
Usage Restrictions
H22M-05
Global
A.5 RAS Features
The server supports a variety of Reliability, Availability, and Serviceability (RAS) features.
You can configure these features for better performance.
For details about how to configure these features, see the
Table A-7
Supported RAS features
Module
Feature
Description
CPU
Corrected Machine Check
Interrupt (CMCI)
Corrects error-triggered interrupts.
Memory
Failed DIMM Isolation
Identifies faulty DIMMs to facilitate
isolation and replacement of the faulty
DIMMs.