Table 5:

 Connections between the XS95 Board and XStend Board resources.

XS95 Pins 

(J2)

XS40 Bus 

(J1,J3,J18)

Power/ GND

DIP Switch

Push-buttons

LEDs

VGA Interface

PS/2 Interface

RAMs

Stereo Codec

8051 Uc

PC Parallel 

Port

Oscillator

Function

UW-FPGA 

BOARD Pin

1

3

LS_0

A0

LED segment; address line

P35

2

4

LS_1

A1

LED segment; address line

P36

3

5

LS_2

A2

LED segment; address line

P29

4

42

Uncommitted XS95 I/O pin

5

6

DIPSW4

LRCK

P13

DIP switch; codec control; uC I/O

P24

6

7

DIPSW1

LCE_

P10

DIP switch; RAM chip-enable, uC I/O port

P19

7

8

DIPSW2

RCE_

P11

DIP switch; RAM chip-enable, uC I/O port

P20

9

13

CLK

XS40/95 oscillator output

10

37

RESET_

XTAL1

Pushbutton; uC clock line

P56

11

9

DIPSW3

MCLK

P12

DIP switch; codec clock; uC I/O port

P23

12

31

Uncommitted XS95 I/O pin

13

14

PSEN_

uC program storage-enable

14

18

S5

RED1

XS Board LED segment; VGA color signal

15

19

S6

HSYNC_

XS Board LED segment; VGA horiz. sync.

17

20

S3

GREEN1

XS Board LED segment; VGA color signal

18

23

S4

RED0

XS Board LED segment; VGA color signal

19

24

S2

GREEN0

XS Board LED segment; VGA color signal

20

29

ALE_

uC address-latch-enable

21

25

S0

BLUE0

XS Board LED segment; VGA color signal

23

26

S1

BLUE1

XS Board LED segment; VGA color signal

25

33

Uncommitted XS95 I/O pin

26

68

KB_CLK

P34

PS/2 keyboard clock; uC I/O port

28

15

JTAG TDI; DIN

28

71

JTAG TDI; DIN

29

17

JTAG TMS

30

16

JTAG TCK; CCLK

30

73

JTAG TCK; CCLK

31

11

Uncommitted XS95 I/O pin

32

27

RD_

uC read line

33

22

Uncommitted XS95 I/O pin

34

28

RDP_

A15

P27

LED decimal-point; address line; uC I/O port

P41

35

10

D_8

AD7

P07

LED; RAM data line; uC muxed address/data line 

P61

36

80

D_7

AD6

P06

LED; RAM data line; uC muxed address/data line 

P62

37

81

D_6

AD5

P05

LED; RAM data line; uC muxed address/data line 

P65

39

35

D_5

AD4

P04

LED; RAM data line; uC muxed address/data line 

P66

40

38

D_4

AD3

P03

LED; RAM data line; uC muxed address/data line 

P57

41

39

D_3

AD2

P02

LED; RAM data line; uC muxed address/data line 

P58

43

40

D_2

AD1

P01

LED; RAM data line; uC muxed address/data line 

P59

44

41

D_1

AD0

P00

LED; RAM data line; uC muxed address/data line 

P60

45

36

RST

uC reset line

46

44

CCLK

PC_D0

Codec control line; PC parallel port output

47

45

CDIN

PC_D1

Codec control line; PC parallel port output

48

46

CS_

PC_D2

Codec control line; PC parallel port output

49

52 GND

Power supply ground

50

47

PC_D3

PC parallel port output

51

48

PC_D4

PC parallel port output

52

49

PC_D5

PC parallel port output

53

50

RS_4

A12

P24

LED segment; address line; uC I/O port

P48

54

51

RS_2

A10

P22

LED segment; address line; uC I/O port

P45

55

56

RS_3

A11

P23

LED segment; address line; uC I/O port

P51

56

57

RS_1

A9

P21

LED segment; address line; uC I/O port

P47

57

58

RS_5

A13

P25

LED segment; address line; uC I/O port

P50

58

59

RS_0

A8

P20

LED segment; address line; uC I/O port

P46

59

72

JTAG TDO; DOUT

59

75

JTAG TDO; DOUT

61

60

RS_6

A14

P26

LED segment; address line; uC I/O port

P49

62

61

OE_

RAM output-enable

63

62

WR_

P36

RAM write-enable; uC I/O port

65

65

CE_

XS Board RAM chip-enable

66

66

DIPSW7

SDOUT P16

DIP switch; codec output data; uC I/O port

P27

68

21

Uncommitted XS95 I/O pin

69

12

Uncommitted XS95 I/O pin

70

69

DIPSW8

KB_DATA

P31

DIP switch; keyboard serial data; uC I/O port

P28

71

70

DIPSW6

SDIN

P15

DIP switch; codec input data; uC I/O port

P26

72

77

DIPSW5

SCLK

P14

DIP switch; codec serial clock; uC I/O port

P25

74

74

Uncommitted XS95 I/O pin

75

78

LS_3

A3

LED segment; address line

P44

76

76

Uncommitted XS95 I/O pin

77

1

Uncommitted XS95 I/O pin

78

2 +5V

+5V power source

79

79

LS_4

A4

LED segment; address line

P38

80

34

PC_D7

PC parallel port output

81

32

PC_D6

PC parallel port output

82

82

LS_5

A5

LED segment; address line

P40

83

83

LS_6

A6

LED segment; address line

P39

84

84

LDP_

A7

LED decimal-point; address line

P37

24,67

67

SPARE_

VSYNC_

P17

Pushbutton; VGA horiz. sync.; uC I/O port

P18

30

Serial EEPROM chip-enable

43

Unconnected

53

Unconnected

54 +3.3V

+3.3V/+5V power supply (4000E/4000XL)

55

PROGRAM

XS40 configuration control

P55

63

Unconnected

64

Unconnected

Содержание XStend

Страница 1: ...and exclusive warranty shall be during the period of warranty specified above and at XESS s option the repair or replacement of the product The foregoing warranty of XESS shall extend to repaired or r...

Страница 2: ...2 9 Daughterboard Connector 12 3 Example Designs for the XStend Board 12 3 1 Using the LEDs and Switches 12 3 2 Using the VGA Interface 16 3 3 Using the PS 2 Keyboard Interface 21 3 4 Using the RAMs...

Страница 3: ...hat the XS40 and XS95 Boards can access through their breadboard interfaces The XStend Board contains resources that extend the range of applications of the XS Boards into three areas The pushbuttons...

Страница 4: ...000XL FPGA with an XC4000E FPGA and remove the J8 jumper to switch the board to 5V operation To use an XS40 Board with the XStend Board insert it into the right most columns of the mounting receptacle...

Страница 5: ...S ACTIVE LOW NET LS_0 LOC P3 NET LS_1 LOC P4 NET LS_2 LOC P5 NET LS_3 LOC P78 NET LS_4 LOC P79 NET LS_5 LOC P82 NET LS_6 LOC P83 NET LDP_ LOC P84 RIGHT LED DIGIT SEGMENT CONNECTIONS ACTIVE LOW NET RS_...

Страница 6: ...and RESET that are accessible from the XS Boards There is a third pushbutton labelled PROGRAM which is used to initiate the programming of the XS40 Board It is not intended to be a general purpose in...

Страница 7: ...CONNECTIONS ACTIVE LOW NET PUSH_SPARE_ LOC P67 NET PUSH_RESET_ LOC P10 2 4 VGA Interface The XStend Board provides the XS Board with an interface to a VGA monitor through connector J5 The XS Board ca...

Страница 8: ...40 and XS95 Boards to the PS 2 interface of the XStend Board expressed as UCF constraints Listing 7 Connections between the XStend PS 2 interface and the XS40 PS 2 KEYBOARD CONNECTIONS NET KB_DATA LOC...

Страница 9: ...AD6 LOC P80 NET AD7 LOC P10 NET A0 LOC P3 LOWER BYTE OF ADDRESS NET A1 LOC P4 NET A2 LOC P5 NET A3 LOC P78 NET A4 LOC P79 NET A5 LOC P82 NET A6 LOC P83 NET A7 LOC P84 NET A8 LOC P59 UPPER BYTE OF ADDR...

Страница 10: ...2 7 Stereo Codec The XStend Board has a stereo codec that accepts two analog input channels from jack J9 digitizes the analog values and sends the digital values to the XS Board as a serial bit stream...

Страница 11: ...K LOC P9 NET LRCK LOC P6 NET SCLK LOC P77 NET SDIN LOC P70 NET CCLK LOC P44 NET CDIN LOC P45 NET CS_ LOC P46 Listing 12 Connections between the XStend codec and the XS95 STEREO CODEC CONNECTIONS NET S...

Страница 12: ...Here are several examples of designs built using the XStend Board coupled with an XS40 or XS95 Board 3 1 Using the LEDs and Switches This example creates a circuit that displays the settings of the DI...

Страница 13: ...DIP switches and press the SPARE and RESET pushbuttons Observe the results on the LEDs Listing 13 ABEL code for testing the XStend LEDs and switches 001 MODULE EXP1 002 TITLE EXP1 003 004 This example...

Страница 14: ...11 050 051 When only the SPARE pushbutton is pressed the DIP switch settings 052 are shown on the right LED display on the XStend Board 053 ELSE WHEN PUSH_SPARE_ 0 PUSH_RESET_ 1 THEN 054 S B0000000 05...

Страница 15: ...ET LDP_ LOC P84 042 043 RIGHT LED DIGIT SEGMENT CONNECTIONS ACTIVE LOW 044 NET RS_0 LOC P59 045 NET RS_1 LOC P57 046 NET RS_2 LOC P51 047 NET RS_3 LOC P56 048 NET RS_4 LOC P50 049 NET RS_5 LOC P58 050...

Страница 16: ...P82 040 NET LS_6 LOC P83 041 NET LDP_ LOC P84 042 043 RIGHT LED DIGIT SEGMENT CONNECTIONS ACTIVE LOW 044 NET RS_0 LOC P58 045 NET RS_1 LOC P56 046 NET RS_2 LOC P54 047 NET RS_3 LOC P55 048 NET RS_4 LO...

Страница 17: ...compiling and testing the design using an XS95 combined with an XStend Board are as follows Synthesize the ABEL code in the EXP2 ABL for an XC95108 CPLD Compile the synthesized netlist using the EXP2...

Страница 18: ...tate so it doesn t interfere 042 043 hcnt ACLR push_reset_ clear counter on active low reset 044 vcnt ACLR push_reset_ clear counter on active low reset 045 hcnt CLK clk horiz cnt increments on each d...

Страница 19: ...t_ 088 delayed_blank CLK clk 089 delayed_blank video_blank 090 091 color mapper that translates each 4 bit pixel into a 6 bit RGB value 092 when the video signal is blanked the RGB value is forced to...

Страница 20: ...TIONS 039 NET VSYNC_ LOC P67 040 NET HSYNC_ LOC P19 041 NET RED1 LOC P18 042 NET RED0 LOC P23 043 NET GREEN1 LOC P20 044 NET GREEN0 LOC P24 045 NET BLUE1 LOC P26 046 NET BLUE0 LOC P25 047 048 PUSHBUTT...

Страница 21: ...2 interface of the XStend Board and displays it on the LEDs In addition if a scan code for one of the keys 0 9 arrives then the numeral will be displayed on the right LED display of the XStend Board...

Страница 22: ...the command XSLOAD EXP3 SVF Press keys on the keyboard and observe the results on the LED displays Listing 19 ABEL code for testing the XStend PS 2 example 001 MODULE EXP3 002 TITLE EXP3 003 004 DECLA...

Страница 23: ...10000 048 H3D B0101101 049 H3E B0000000 050 H46 B0000100 051 H45 B0001000 052 053 END EXP3 Listing 20 UCF file for PS 2 XStend example with XS40 001 MICROCONTROLLER PINS 002 NET RST LOC P36 ACTIVE HIG...

Страница 24: ...P70 012 NET KB_CLK LOC P26 013 014 RIGHT LED DIGIT SEGMENT CONNECTIONS ACTIVE LOW 015 NET RS_0 LOC P58 016 NET RS_1 LOC P56 017 NET RS_2 LOC P54 018 NET RS_3 LOC P55 019 NET RS_4 LOC P53 020 NET RS_5...

Страница 25: ...how the connections between the XS40 Board and XS95 Board and the resources on the XStend Board respectively Both tables contain the same information but are sorted according to the ordering of the XS...

Страница 26: ...ata line uC muxed address data line P58 40 43 D_2 AD1 P01 LED RAM data line uC muxed address data line P59 41 44 D_1 AD0 P00 LED RAM data line uC muxed address data line P60 42 4 Uncommitted XS95 I O...

Страница 27: ...2 LED RAM data line uC muxed address data line P58 43 40 D_2 AD1 P01 LED RAM data line uC muxed address data line P59 44 41 D_1 AD0 P00 LED RAM data line uC muxed address data line P60 45 36 RST uC re...

Страница 28: ...ing the shunt on this jumper disables the left RAM U5 by pulling its chip select pin high J17 Removing the shunt on this jumper disables the right RAM U6 by pulling its chip select pin high J11 Placin...

Страница 29: ...XStend Bus Connections...

Страница 30: ...XStend RAMs...

Страница 31: ...XStend Analog I O...

Страница 32: ...XStend Stereo Codec...

Страница 33: ...XStend Switches LEDs VGA Interface and PS 2 Interface...

Страница 34: ...XStend Board Layout...

Отзывы: