file:///C|/Documents%20and%20Settings/Miz%20B/My%...GTA/Nuvera%209.0%20UGTA_FINAL/English/spec_80.htm (1 of 2)8/13/2008 4:44:12 PM
Electrical and Environmental Specifications
The print engine, which includes the FreeFlow Print Server, requires:
Frequency
50/60 hz
Voltage
Protection 115-127/200-220V 2 phase, 3 wire+ PE
Line Current 24A or 40A, Frequency 60 and Branch Cir 30A or 50A
Protection 200-240 V
Line Current 24A, Frequency 50 and Branch Cir 30A
Amps
Dedicated 30 amps (Europe)
Dedicated 50 amps (US, Canada and Japan)
The outlets/circuits can not be shared with any other devices or equipment. Optional 50 amp Adapter Box and 30A Extension Box with
appropriate circuit breakers are available.
Receptacle NEMA Part Number
14-30 R (NASG)
Temperature and Humidity
Recommended 50 degrees F to 87 degrees F (10 C to 30.6 C)
15% relative humidity (minimum) to 85% relative humidity (maximum)
Altitude
Between 0 to 6000 ft (1828.8m) above sea level
Heat Emission
Approximately 2,018 BTU/hour (standby) and 11,600 BTU/hour (running)
Power Consumption
Approximately 0.658 kw maximum (standby) and 4.150 kw maximum (running). For information on power consumption, see
Power
Saver Mode
.
US/Canada Line Voltage
:
EU Line Voltage: