02/2000
2-11
DocuPrint N2125
RAP 1
Status Indicator Repair Analysis Procedures
Initial Issue
RAP 1 AC Power
Initial Actions
Disconnect the AC power cord from the wall outlet.
WARNING
Improper connection of the grounding conductor can result in the risk of electrical
shock. The following must be observed:
•
Never use a ground adapter plug to connect the machine to a power source.
•
Never attempt any maintenance function which is not specifically called out in the
service procedures.
•
Never remove any covers which are fastened with screws, unless so instructed in
the service procedures.
CAUTION
If any of the voltage measurements are not as specified in the following steps, the cause must
be corrected. Caution the customer NOT to connect the machine to the wall outlet. Advise the
customer that a licensed electrician must correct the wiring. Do not attempt to correct the wir-
ing yourself. If you later find the condition has not been corrected, inform your manager in writ-
ing of the improper wiring.
Procedure
Perform one of the following line voltage checks:
US, XCI, and AO (115 VAC)
. Perform the following:
Measure the AC voltage between AC Line and Neutral, between AC Line and Ground, and
between AC Neutral and Ground. The voltage between Line and Neutral and between Line and
Ground is 90 to 140 VAC and the voltage between Neutral and Ground less than 3 VAC.
Figure 1 US, XCI, and AO (115 VAC) Outlet.
XL, UK and AO (220 VAC)
. Perform the following:
Measure the AC voltage between Line and Neutral, between Line and Earth/Ground, and
between Neutral and Earth/Ground. The voltage between Line and Neutral and between Line
and Earth/Ground is 198 to 264 VAC and between Neutral and Earth/Ground is less than 3
VAC.
Figure 2 XL, UK, and AO (220 VAC) Outlet.
XL, Europe (220 VAC)
. Perform the following:
Measure the AC voltage between the supply pins, then between a supply pin and earth, then
between the other supply pin and earth. The voltage is 198 to 264 VAC between the supply
pins and between one of the supply pins and earth. Between the other supply pin and earth is
less than 3 VAC.
Figure 3 XL, Europe (220 VAC) Outlet.
The voltage measured is correct.
Y
N
Inform the customer of insufficient voltage or improper wiring.
Check the continuity through all connections of the power cord. The measurement is less
than 10 ohms for each connection.
Y
N
Replace the power cord (
), as applicable.
.
manuals4you.com
manuals4you.com
Содержание N2125N - DocuPrint B/W Laser Printer
Страница 11: ...02 2000 1 2 DocuPrint N2125 Initial Issue Service Call Procedures...
Страница 17: ...02 2000 1 8 DocuPrint N2125 1 5 Initial Issue Service Call Procedures...
Страница 19: ...02 2000 2 2 DocuPrint N2125 Initial Issue Status Indicator Repair Analysis Procedures...
Страница 21: ...02 2000 2 4 DocuPrint N2125 Introduction Measurements Initial Issue Status Indicator Repair Analysis Procedures...
Страница 27: ...02 2000 2 10 DocuPrint N2125 Error Code Tables Initial Issue Status Indicator Repair Analysis Procedures...
Страница 61: ...02 2000 2 44 DocuPrint N2125 RAP 50 RAP 51 Initial Issue Status Indicator Repair Analysis Procedures...
Страница 65: ...02 2000 2 48 DocuPrint N2125 RAP 55 RAP 56 Initial Issue Status Indicator Repair Analysis Procedures...
Страница 69: ...02 2000 2 52 DocuPrint N2125 RAP 60 RAP 61 Initial Issue Status Indicator Repair Analysis Procedures...
Страница 73: ...02 2000 2 56 DocuPrint N2125 RAP 66 Initial Issue Status Indicator Repair Analysis Procedures...
Страница 75: ...02 2000 3 2 DocuPrint N2125 Initial Issue Image Quality Repair Analysis Procedures...
Страница 103: ...02 2000 4 4 DocuPrint N2125 Introduction Initial Issue Repair Adjustment...
Страница 111: ...02 2000 4 12 DocuPrint N2125 REP 1 11 REP 1 12 Initial Issue Repair Adjustment...
Страница 117: ...02 2000 4 18 DocuPrint N2125 REP 2 5 Initial Issue Repair Adjustment...
Страница 135: ...02 2000 4 36 DocuPrint N2125 REP 4 10 Initial Issue Repair Adjustment...
Страница 153: ...02 2000 4 54 DocuPrint N2125 REP 7 4 REP 7 5 Initial Issue Repair Adjustment...
Страница 165: ...02 2000 4 66 DocuPrint N2125 REP 9 12 Initial Issue Repair Adjustment...
Страница 177: ...02 2000 4 78 DocuPrint N2125 REP 10 18 Initial Issue Repair Adjustment...
Страница 191: ...02 2000 4 92 DocuPrint N2125 REP 11 19 REP 11 20 Initial Issue Repair Adjustment...
Страница 201: ...02 2000 4 102 DocuPrint N2125 REP 12 13 REP 12 14 Initial Issue Repair Adjustment...
Страница 213: ...02 2000 4 114 DocuPrint N2125 REP 13 17 Initial Issue Repair Adjustment...
Страница 215: ...02 2000 4 116 DocuPrint N2125 ADJ 1 1 Initial Issue Repair Adjustment...
Страница 217: ...02 2000 5 2 DocuPrint N2125 Initial Issue Parts list...
Страница 241: ...02 2000 6 2 DocuPrint N2125 Initial Issue General Procedures Information...
Страница 243: ...02 2000 6 4 DocuPrint N2125 Introduction Initial Issue General Procedures Information...
Страница 263: ...02 2000 6 24 DocuPrint N2125 GP 2 11 Initial Issue General Procedures Information...
Страница 287: ...02 2000 6 48 DocuPrint N2125 GP 4 1 Initial Issue General Procedures Information manuals4you com manuals4you com...
Страница 289: ...02 2000 6 50 DocuPrint N2125 GP 4 1 Initial Issue General Procedures Information Figure 4 PCL Menu...
Страница 293: ...02 2000 6 54 DocuPrint N2125 GP 4 1 Initial Issue General Procedures Information Figure 9 Ethernet Menu...
Страница 295: ...02 2000 6 56 DocuPrint N2125 GP 4 1 Initial Issue General Procedures Information Figure 11 Novell Menu...
Страница 297: ...02 2000 6 58 DocuPrint N2125 GP 4 1 Initial Issue General Procedures Information...
Страница 299: ...02 2000 6 60 DocuPrint N2125 GP 5 1 Initial Issue General Procedures Information...
Страница 301: ...02 2000 7 2 DocuPrint N2125 Initial Issue Wiring Data...
Страница 307: ...02 2000 7 8 DocuPrint N2125 Base Engine Initial Issue Wiring Data Figure 5 Block Diagram 2 of 2...