Installation
Chilli Dimmer 73-853-00 Issue 8
Page 11 of 30
Figure 2 - 9: Chilli Pro 1210 HF Dimmer - HF Controller Outputs
Load Connections
12 Channel HF Unit
The
switched
outputs
are
connected to the terminal strips
located on the left hand side of the
unit. The outputs will accept a
maximum 6mm
2
cable.
The outputs are phase interleaved
and the terminals are labelled L1,
E, N1, L2, E, N2, etc. and will
accept a maximum 6mm
2
cable.
Do not use a common neutral for
multiple loads.
The HF controller outputs are
connected to the terminal strip
located on the right hand side of
the unit and will accept a maximum
2.5 mm
2
cable.
The connectors are in 2 parts and
the screw terminal parts may be
removed from the PCB to ease
making the connections.
If removed for wiring, ensure that
the orientation is correct when
replacing the connectors.
NOTE - The HF controller
outputs in this product are
electrically isolated from mains
earth and mains phase.
They are only intended for
connection to electronic ballasts
for fluorescent fittings.
They are not intended to control,
and should not be connected at
any time, to any earth referenced
electronics.