Petrel-X User Manual 1.1 

 

12 

Commands 

Below are commands for the Petrel-X. 

 

Each  command  starts  with  a  dollar  sign  (

$

).  The  Bluetooth  app  prepends  this 

automatically. 

 

If a parameter is possible (marked with an X below), that parameter can be an integer to 
change the setting, or can be left blank to query the current settings. Please refer to the 

Settings and Defaults

 section below for limits and defaults. 

Command 

Description 

 

 

aisname [name] 

Set the ais name that the unit will use in its AIS messages. Maximum 20 
characters, using uppercase letters (A-Z) or numbers (0-9). If no name is 
given, the unit will just print its current name. 

settings 

Show all settings and thresholds. 

gpstimeout X 

Duration GPS runs before shutting off, in minutes. 

wsthresh X 

Change or query the water/underwater threshold.  

wsperiod X 

The rate  of  water-sense  (or  tilt-sense)  checks  while  in the  underwater 
mode.  Sent  as  an  integer  representing  the  number  of  seconds  in 
between water checks. 

wsbackper X 

The period of backup GPS checks while in underwater mode, in hours. 

usetilt X 

Send parameter 

1

 to use tilt-sensing instead of water-sensing to detect 

surfacing (upright = surfacing; inverted = submerged).  
Send parameter 

0

 to use water-sensing instead of tilt-sensing (default).  

readsensor 

Perform a reading with each sensor (voltage, water-sense and tilt-sense). 

Note

: Results will not be printed until the 

viewsensor

 command is sent. 

viewsensor 

Display the latest sensor readings. 

sysinfo 

The unit will display system information. 

resetnow 

The unit will reset itself. No settings will be changed. 

skipbt 

The unit will disconnect from any Bluetooth connection, exit Bluetooth 
mode and proceed directly to GPS Search mode. 

factorydefaults 

Sets all the user-adjustable settings (except the AIS name) back to their 
default  values.  The  AIS  name  has  to  be  manually  changed  with  the 

$aisname

 command. 

ver 

Show the unit’s current firmware and hardware version, as well as some 

other information about the unit. 

 

 

 

Содержание Petrel-X

Страница 1: ...1 Petrel X User Manual Submersible AIS Compatible Beacon Version 1 1 April 2024...

Страница 2: ...el X is the successor to the Petrel For the manual of the original Petrel please see here Version History Version No Date Description 1 0 Apr 2024 Initial release 1 1 Apr 2024 Converted consumption to...

Страница 3: ...ating Modes 6 Powering the Device 6 Using the Magnet Switch 6 Self Test Failure Codes 7 Water Sensing 11 Tilt Sensing 11 Bluetooth 11 Commands 12 Settings and Defaults 13 Maintenance 14 Battery Pack 1...

Страница 4: ...to trigger the water sense 3 The magnet switch for turning the Petrel X on and off is located directly below the glass 4 The meeting point of the electronics head and battery chamber is torqued and sh...

Страница 5: ...he Petrel X is next to a wall Do not use conductive material at the top of the Petrel X around the glass lens this will cause the water sensor to fail Operational Tips Connecting power or power cyclin...

Страница 6: ...ic switch For this reason always remove the batteries if the Petrel X is being stored long term Using the Magnet Switch The Petrel X can be turned ON and OFF using an external magnet near an internal...

Страница 7: ...X will flash its RED LED in an error code pattern to indicate which criteria failed If multiple criteria fail only the highest priority failure code will be displayed These patterns are in Morse code...

Страница 8: ...Bluetooth connection could be made the magnet can be used to reset the unit to re enter Bluetooth mode While in Bluetooth mode both the AIS and GPS functionality of the unit are inactive The unit will...

Страница 9: ...d because the Petrel X transmits AIS message type 21 which fills two AIS slots A Petrel X s AIS transmissions contain an MMSI and an AIS name The AIS name is made of up to 20 characters which can be a...

Страница 10: ...n false positives To combat this problem the Petrel X has a backup counter that automatically returns the unit to GPS Search Mode when it expires In the event the unit surfaces but cannot sense the la...

Страница 11: ...mal water sense checks When using tilt sensing instead of water sensing being upright antenna pointed towards the sky is considered Surfaced and will cause the unit to go to GPS Search Mode The Petrel...

Страница 12: ...Sent as an integer representing the number of seconds in between water checks wsbackper X The period of backup GPS checks while in underwater mode in hours usetilt X Send parameter 1 to use tilt sensi...

Страница 13: ...d and surfaced Water Sense Period 30s 5s 600s The rate at which the water sense measurement is taken GPS Backup Period 12 hours 1 hour 48 hours Time between backup GPS checks Use Tilt 0 0 1 When ON 1...

Страница 14: ...nsert is vacuum sealed to the full length of the inside of the battery chamber to prevent internal shorting To replace the batteries Slowly unscrew the bottom endcap of the Petrel X Any batteries alre...

Страница 15: ...rel X All Petrel Xs employ O ring size 2 031 N70 in their endcaps Replacing O Rings To replace the O Ring Remove the old O ring and clean all dirt away from the threads and grooves where it was seated...

Страница 16: ...Operation Mode 320mW AIS Transmission 50ms duration 1 45W Bluetooth Mode 40mW Underwater Mode 480 W Device Off 300 W Batteries should be removed if the device is entering storage Electronics Digital C...

Страница 17: ...or Pinout Petrel X Remote Head Pin Number Name 1 N C 2 N C 3 N C 4 V Battery 5 N C 6 Ground Battery Pack Pin Number Name 1 N C 2 N C 3 N C 4 V Battery 5 N C 6 Ground Connector MCBH 6F TI External View...

Страница 18: ...anty is void if failure of the product has resulted from accident abuse or misapplication Any replacement product will be warranted for the remainder of the original warranty period or ninety 90 days...

Отзывы: