General Description 

The Resilient Surface Iridium satellite mooring location beacon continuously monitors location 
for mobile surface assets and/or instrument moorings. Resilient makes use of the bi-directional, 
global,  real  time  Iridium  satellite  Short  Burst  Data  (SBD)  network  in  combination  with  GPS 
position location.  Resilient’s sleek tubular design and internal dual Iridium/GPS antennas located 
at each end cap allow it to be easily retrofitted into a variety of surface mounts. Even surface 
installations which capsize may be able to transmit location information

Inside the Resilient is a 9603 Iridium satellite Short Burst Data core radio transceiver, a specialized 
low power Xeos digital controller with GPS, Iridium antenna and GPS antennas. 

Resilient is intended for surface deployments and should not 
be deployed in situations which exceed 100m in depth. Xeos 
Technologies  Inc.  (Xeos)  manufactures  other  specific 
products  for  either  surface,  or  subsurface  applications  to 
depths of 11,000 m. 

Se

www.xeostech.com

 for details or call (902) 444-7650.   

Theory of Operation 

The Resilient is intended for providing regular location information on high value assets at the 
surface, drifting or moored. After being activated, the  Resilient is deployed at the surface and 
begins  sending  location messages  as  per  the  user  settings.  The  internal battery  pack provides 
over 1500 messages or up to a 2-year deployment.

   

Operators can communicate with the surface deployed Resilient via Iridium using commands sent 
through WGMS. Status information can be obtained, including the health of the GPS system and 
battery voltage. Timings are settable, and the default is one message every 12 hours. If you need 
to make a change to settings, the Resilient will receive the command to change the timing the 
next time it checks for messages, as much as 12 hours after the command is sent. 

The Resilient will continue to send position messages based on the timings, until it is manually 
turned off or the battery pack drops below the minimum voltage requirement of 7V

 

Due to the location of dual Iridium/GPS antennas at both ends of the enclosure, the Resilient will 
continue to try and send position messages when inverted or capsized. 

Содержание Resilient

Страница 1: ...ONYX User Manual 3 0 1 Resilient User Manual SURFACE IRIDIUM GPS BEACON Version 2 0 January 2020...

Страница 2: ...RoverWGMS firmware build 6058 If you wish to acquire the latest firmware for your device contact support xeostech com Version History Version No Date Description 1 0 Oct 2017 Base Document 1 1 Jan 201...

Страница 3: ...ower Up 8 Battery Installation 8 Magnet 8 Confirm Transmission 8 Operation 8 Understanding Position Information 9 Iridium Doppler position 9 Global Positioning System 10 On Off Modes 11 Using the Magn...

Страница 4: ...eleting the Flash Memory 21 Bluetooth 22 Other Commands 23 Troubleshooting 24 Deployment of the Resilient 26 Antennas 26 Power Consumption 26 Sample Power Consumption Patterns 26 Understanding the Til...

Страница 5: ...of 11 000 m See www xeostech com for details or call 902 444 7650 Theory of Operation The Resilient is intended for providing regular location information on high value assets at the surface drifting...

Страница 6: ...3 transceiver This service is a global including the Polar Regions two way real time and email based data delivery service with a maximum outbound from beacon message size of 340 bytes and a maximum i...

Страница 7: ...or from the Resilient however the messages from the Resilient in this format are not human readable XeosOnline is a web based monitoring system which allows users to view and manage information from t...

Страница 8: ...hing GREEN LED on the top of the device remains solid The green LED will flash again while the device completes power up Confirm Transmission Turn the device on and place it outside in view of as much...

Страница 9: ...of the device in the subject line regardless of its name on XeosOnline sbdservice sbd iridium com All messages from Iridium devices come from this address MOMSN 5866 Mobile Originating Message Serial...

Страница 10: ...dent always 80 that the device sending the message is within a circle 2 kilometers in radius with the Lat Long given as the centre of that circle The higher the CEPradius value the larger the circle a...

Страница 11: ...rmittent beep and flash the red LED at the top for 5 minutes or until the batteries have been corrected or replaced If this behavior persists even if the batteries are full and oriented correctly this...

Страница 12: ...Xeos Online User Manual and Xeos Organizational Administrator Manual If you do not already have a copy please contact support xeostech com 1 Using your web browser go to http online xeostech com 2 Lo...

Страница 13: ...Change to configuration only takes place once the Resilient receives the message That means that if the Resilient is set to check messages hourly it will not change its operational behavior until it...

Страница 14: ...Resilient User Manual Version 2 0 14 Configuration of the Resilient The Resilient has a combination of preset behaviors and configurable parameters Below is an outline of its normal default behavior...

Страница 15: ...Used if none of the following modes are triggered Timer 1 Start up Used for the first hour after the unit is powered on Timer 2 Alarm Used once the unit is inverted or exits its watch circle Timer 3 L...

Страница 16: ...l limit on the ratio of GPS fixes to Iridium checks Regardless the method being used to communicate with the Resilient timer commands are always the same format Example 1 timer SBD 2 10m Changes the S...

Страница 17: ...functionality is enabled the specifics of the user s circle can be implemented Setting the Watch Circle The watch circle parameters can be set by sending the setcircle command using this format setcir...

Страница 18: ...removal from enclosure to reach USB port 2 Take note of the COM port number in Control Panel Device Manager In this case COM8 Connect Using Terminal Emulator 1 Download terminal emulator software 2 C...

Страница 19: ...ion send the command aenbl 0 Setting Up Encryption on XeosOnline 1 Log in to XeosOnline and click on the Admin button at the top of the screen 2 Ensure that your organization is selected in the Organi...

Страница 20: ...h Memory Connect to the Resilient using the Bluetooth App for Android If The device does not appear as advertising on the main page do one of the following Power cycle the device with a magnet or temp...

Страница 21: ...GPS positions it is prudent to clear the flash memory after extended deployments To delete the flash records send the command flasheraseuserdata The deleting process can take up to 30 seconds after wh...

Страница 22: ...power up or reset After this time the device will need to either be reset or the Bluetooth power on command btpwr 1 must be sent to the device through Iridium for Bluetooth to resume advertising If th...

Страница 23: ...inutes btName X Set Bluetooth name for the Resilient btpcycle Power cycle Bluetooth batt Show battery status settings Show all settings stats Show statistics since last powerup reset statsL Show Lifet...

Страница 24: ...ilient to use the bottom Iridium antenna to check the RSSI level greater than zero The Status page of Bluetooth app shows most recent occurrance of these stats o Change the location of the device plac...

Страница 25: ...should not Watch Circle or Inversion Watch circle centre is in the wrong location or an unsatisfactory radius o setcircle X Y Z to change circle and radius o setcircle 0 0 Z to change radius only o W...

Страница 26: ...amounts of other materials may also cause interference Testing of concealed installations is strongly recommended Power Consumption The Resilient has an internal battery enclosure that holds 18 AA bat...

Страница 27: ...0888 mA 971 25 days 32 38 months 2 70 years 1699 83 days 56 66 months 4 72 years Calculations subject to change without notice Xeos conducts ongoing battery life and power consumption tests to provid...

Страница 28: ...Installation Test the installation by checking the email addresses to which the Iridium account is sending notifications or Xeos Online Xeos Online will display the last known position of the device a...

Страница 29: ...ery Compartment Source Repair or replacement must be done by Xeos Technologies Inc 1 902 444 7650 or support xeostech com Only use new approved batteries for deployments In the event used batteries ar...

Страница 30: ...for seating the O Ring NOTE It is very important to be aware of where the O ring is sitting in the two O Ring locations If the O ring is not sitting perfectly in its groove there will not be a perfec...

Страница 31: ...PS Receiver 48 Channel SiRFstarIV GSD4e GPS chip Iridium Hardware 9603 Modem Electrical Supply 18 AA batteries Lithium or alkaline Operating Voltage 9 32V Nominal Voltage 13 5V Battery Capacity 3 0 Am...

Страница 32: ...Resilient User Manual Version 2 0 32 Specifications subject to change without notice...

Страница 33: ...ited Warranty is void if failure of the product has resulted from accident abuse or misapplication Any replacement product will be warranted for the remainder of the original warranty period or ninety...