Resilient User Manual Version 2.0
15
Resilient Timer Intervals
The following are the parameters for each mode:
Timer
T0
<T1>
T2
T3
T4
Min-Max
SBD
12h
10m
10m
1d
12h
5m – 1d
GPS
12h
10m
5m
1d
12h
5m – 1d
Legend
SBD
SBD (Iridium) transmission interval
GPS
GPS acquisition interval
T0 – T7
Timer number
<T#>
Timer currently in use
#s/m/h/d
Interval in seconds/minutes/hours/days
Min
Minimum allowed interval for this timer
Max
Maximum allowed interval for this timer
Timers
Timer 0
Normal
Used if none of the following modes are triggered
Timer 1
Start-up
Used for the first hour after the unit is powered on
Timer 2
Alarm
Used once the unit is inverted or exits its watch circle
Timer 3
Low Battery Used when there is a low battery
Timer 4
No GPS Fix
Used when the GPS module fails to acquire a fix
The default timer settings of the Resilient are suitable for most use cases.
Timers 5 - 7 are not used in the Resilient.
Timer Command
The $timer command will return the timer intervals all configurable settings. The response will
also be returned when timers are changed:
The timer string returned includes a summary of all timers. The first five timers (0 – 4) are used.