Xi-100b User Manual Version 4.1
16
Once the Tunnel is created, individual connection methods must be established. A maximum of
10 is possible and requires this information to set up:
Field Name
Description
Name
Give the tunnel a descriptive name
Local Port
The port of the XeosOnline server, based on the Iridium Listen Port. Xeos will
supply this value
Remote IP
The IP address of the peripheral device connected to the Xi-100b
Remote Port
The Port of the remote device connected to the Xi-100b
Protocol
Choose the protocol (UDP or TCP) to be used by the RUDICS connection
There is also the ability to have the connection method disabled (checkbox) or deleted entirely
(minus symbol) which Xeos will not employ unless requested to do so.
Configuring the Xi-100b for RUDICS
The Xi-100b is setup to work with the Quanterra Q330 seismic system by default.
To connect to an alternative device, several settings must be changed before deployment.
RUDICS settings
1.
For devices using Ethernet to connect to the Xi-100b, RUDICS must be set to Ethernet
mode, this is done by entering the command $rdcsserial 0
2.
Set the IP address of the Xi-100b using the command format $eip 192 168 0 2 using a
space instead of decimal notation. The default IP value is 192.168.0.130
3.
Set the Net Mask using $enmask 255 255 255 0, again using spaces instead of decimals.
The default is 255.255.255.0
4.
By default, the Xi-100b acts as a router with a network address of 192.168.0.1
This can be changed with the command $erouter 192 168 0 1 using spaces instead of
decimals.
5.
The RUDICS number for the Xi-100b to dial on the start of the session; this is the 8816
number given to the RUDICS group the SIM is a member of. Leading zeroes are required
to add this setting to the Xi-100b. Ex. $rdcsnum 008816000009999
Содержание Alert Geomatics Xi-100b
Страница 1: ...Xi 100b User Manual GLOBAL SATELLITE TRANSCEIVER Version 4 1 April 2019...
Страница 25: ...A 05 018 1 Xi 100b Port 1 Power Supply External Sensor DB9...
Страница 26: ...Xi 100b User Manual Version 4 1 2 A 05 018 3 Xi 100b Port 1 Power Supply...
Страница 27: ...Xi 100b User Manual Version 4 1 3 A 05 019 1 Xi 100b Port 2 Ethernet RJ45 Serial DB9...
Страница 28: ...Xi 100b User Manual Version 4 1 4 A 05 019 2 Xi 100b Port 2 Q330 Serial QNet...
Страница 29: ...Xi 100b User Manual Version 4 1 5 A 05 019 4 Xi 100b Port 2 Q330 Serial Ethernet RJ45...
Страница 30: ...Xi 100b User Manual Version 4 1 6 A 05 019 5 Xi 100b Port 2 Q330 Serial...
Страница 31: ...Xi 100b User Manual Version 4 1 7 A 05 027 Xi 100b Port 2 Xi 100b Programming Cable DB9...
Страница 32: ...Xi 100b User Manual Version 4 1 8 A 05 028 Xi 100b Port 2 Q330 QNet...