Xi-100b User Manual Version 4.1
14
Timer
Description
Ver
Xi-100b Firmware version
Uptime
Time (DD:MM:SS) since last power-up or reset
Vb
Supply voltage currently read by the Xi-100b
Temp
Shows current temperature read by the Xi-100b (Celsius)
Q330
Shows if Q330 functionality is enabled/disabled (Y/N)
Heater
Shows if heater functionality is enabled/disabled (Y/N), shows temperature
heater needs to reach to shut off if turned on
Sensor
Shows if external sensor functionality is enabled/disabled (Y/N)
Rudics
Shows if RUDICS functionality is enabled/disabled (Y/N), routing (Serial/Ethernet),
RUDICS Mode (Off, Single, Continuous), Continuous minutes, Cool-down period
Dial#
RUDICS number dialed to establish RUDICS connection
Ethernet Shows if Ethernet is enabled/disabled (Y/N) for interface with peripheral device
Badpg
Number of bad flash pages in memory
IP
IP address set in the Xi-100b
Mask
Subnet mask set in the Xi-100b
DefRtr
Gateway IP set in the Xi-100b
Mo24
Mobile-originating messages, last 24 hours. Number of messages sent by the Xi-
100b in the last day.
Mt24
Mobile-terminating messages, last 24 hours. Number of messages received by the
Xi-100b in the last day.
QQVMap Q330 Quickview channel map (bitmap, hex)
RTMax
RUDICS temperature Max
RVMin
RUDICS Voltage minimum
SBD
Iridium timer; shows Enabled/Disabled (Y/N), followed by repetition rate
ESP
Sleep mode timer; shows Enabled/Disabled (Y/N), followed by repetition rate
QQV
Q330 Quickview timer; shows Enabled/Disabled (Y/N), followed by repetition rate
QST
Q330 Status timer; shows Enabled/Disabled (Y/N), followed by repetition rate
SEN
External sensor timer; shows Enabled/Disabled (Y/N), followed by repetition rate
SIM
SIM of the modem; if blank, the modem has not sent this information to memory.
SIM only shows number here if contact has been made with the Iridium network;
therefore an Iridium antenna is required for this information.
IMEI
IMEI of the modem; if blank, the modem has not sent this information to memory
Using RUDICS
The Xi-100b allows you to establish a direct TCP/IP socket connection between a local terminal
and your remote device. RUDICS itself has no underlying protocol.
If you are using the XeosOnline server, Xeos will provide you with the necessary Local Port and IP
for tunnel configuration. If your SIM is provisioned through another provider other than Xeos,
those local IPs and ports must be forwarded to that party.
Содержание Alert Geomatics Xi-100b
Страница 1: ...Xi 100b User Manual GLOBAL SATELLITE TRANSCEIVER Version 4 1 April 2019...
Страница 25: ...A 05 018 1 Xi 100b Port 1 Power Supply External Sensor DB9...
Страница 26: ...Xi 100b User Manual Version 4 1 2 A 05 018 3 Xi 100b Port 1 Power Supply...
Страница 27: ...Xi 100b User Manual Version 4 1 3 A 05 019 1 Xi 100b Port 2 Ethernet RJ45 Serial DB9...
Страница 28: ...Xi 100b User Manual Version 4 1 4 A 05 019 2 Xi 100b Port 2 Q330 Serial QNet...
Страница 29: ...Xi 100b User Manual Version 4 1 5 A 05 019 4 Xi 100b Port 2 Q330 Serial Ethernet RJ45...
Страница 30: ...Xi 100b User Manual Version 4 1 6 A 05 019 5 Xi 100b Port 2 Q330 Serial...
Страница 31: ...Xi 100b User Manual Version 4 1 7 A 05 027 Xi 100b Port 2 Xi 100b Programming Cable DB9...
Страница 32: ...Xi 100b User Manual Version 4 1 8 A 05 028 Xi 100b Port 2 Q330 QNet...