5.
Maintenance
The maintenance of the equipment shall be carried out by professionals,
such as arbitrary demolition and maintenance, which may cause damage to
the equipment.When repairing and replacing parts, please choose the
original parts, any replacement of unqualified parts, may cause damage to
the equipment or be harmful to the Operation safety.
5.1.
Daily Maintenance
Daily Check Items:
A. Temperature and Humidity: the temperature is between the 20
℃
~26
℃
and the humidity
is between the 45~70%.
B. Indoor environment: Requires air cleaning, non-corrosive gas.Confirm that there is no
debris in the range of screw, slide rails and robotic arm movement.
C. Check to see if there is no clutter on the fixed camera and if the lens is clean.
D. Check that the suction nozzle is dirty, deformed, clean or replace the suction nozzle.
E. Check that the tape gun is properly placed.
5.2.
Regular Maintenance
Equipment is recommended to do the regular maintenance once 1~2 months.
Periodically check items:
1) Maintenance of air pressure circuit
Detect air pressure loops without leaks, remove or clean air pressure sources and air
pressure adjustments. Detect voltage regulator pressure regulating valve and confirm air
pressure (0.5Mpa).
Detect the pressure switch and confirm that the alarm air pressure is set to 0.5Mpa.
Clean Vacuum occurrence Kit filter sponge, as appropriate to replace.
Check the action of Z-axis cylinder and suction nozzle and blow clean suction nozzle.
2) Maintenance of transmission mechanism
X, Y, Z axis slide rail and ball screw need lubricating oil maintenance.
Check the X, Y, Z axis servo motor transmission belt has no loosening, wear, fracture.
The position of the motor and the balance of the belt are confirmed.
Check the fastening status of all screws and distribution cabinet screws on the machine,
be sure to confirm.
Check that the connectors and connectors are loose.
3) Maintenance and repair of the device for taking and releasing tablets.
4) Check the rotary motor. Check that the Z-axis cylinder is telescopic properly.