4.6 Device Operation Window
According to the references provided by the manufacturer, the operations, which can
be executed during the programming, are displayed in this window. After the
preparation for the programming is made, users can execute the corresponding
operation items according to their needs.
Following is the window for Atmel At89c51.
The function displayed may vary from chip to chip. The frequently-used operations
are explained below:
Auto: The automatic programming mode. The function executes a series of
operations on the device in a defined order. Please refer to the “Edit Auto” in the
menu.
Program: Programming the chip with the data in the buffer. The function writes
the data from the buffer into the chip. The Verify function is performed in two
modes. One mode is verifying while programming. This method basically ensures
the correctness of programming after programming a chip is finished. If an error
occurs, the error message will be displayed and the process will be ceased. The