background image

B

Test

 

Cylinder

 

and

 

Power

   

Cross

-

Head

 

screw

 

driver

An

 

ordinary

 

tool

 

and

 

should

 

be

 

prepared

 

by

 

user

.

User

 

prepare

 

TOOLS

Push

 

and

 

pull

 

to

 

open

 

it

Cylinder

 

cover

 

opener

This

 

tool

 

is

 

used

 

to

 

remove

  

the cylinder

 

cover

Vendor

 

offer

 

it

 

free

Inner

 

hexagon

 

screw

 

driver

This

 

tool

 

is

 

necessary

 

while

 

install

 

cylinder

 

in

 

mortise

.

Vendor

 

offer

 

it

 

free

Test

 

Thumb

 

Turn

Beep

   

Installation

 

steps

 

  

1.

Punch holes

Each lock installation requires holes on the door.
To punch the holes you must use the template correctly.
Take out the template.On the front side of the template it shows
the edge of the door (on the right direction).
Please always aim the edge of the door line at the real door.
You should turn the template reverse to let it suite another face of 
the door.
Firstly mark the height line on both faces of the door.
(height line start from the handle center and it is away from the 
ground 1.0-1.1m) Then mark the balance holes by a pencil or 
markingpen.Paste the flank face template on the door by aligning 
the main. Mark the mortise hole.
Punch all holes by the electric 
drill according the marks.

Template should be use repeatly 
for all doors punching.
Holes size and position may 
different for different model lock 
please check it carefully before 
start punch.
Holes must not bigger than the 
size on the template otherwise 
the holes may exposed outside.
The mortise hole on the flank 
must be punched at enough 
depth otherwise the mortise 
could not be placed in.

Put the mortise into the hole and 
holding it square to the door 
edge, draw around the faceplate. 
Remove the mortise and score 
the outline with a stanley knife to 
avoiding splitting when 
chiseling. Chisel a rebate to allow 
the latch to fit flush to the 
surface.Fix the mortise with the 
screws, with the bevel towards 
the door frame.

3.

Fix the cylinder

Insert the cylinder from front and 
tight the screws from back by 
using the inner hexagon screw 
driver

4.Install front and back boby:

Export the cable from the hole,put the axis,connect the lock front 
and back boby with link cable through the hole, ensure plug 
correctly connect with the back boby slot,then connect inside and 
outside with square shaft,ensure the lock plate and the mortise 
connection are reliable,finally screw the lock plate in the door.

5.Install the battery and Battery Pack Cover:

After confirm the positive direction of the battery,closes Pack Cover.

6.Test:

After the installment completed,check if the basic function 
works is necessary.

Test Cylinder and Power
Instert the emergency key and trun it to make the latch retracted, 
if the lock shows blue light and one beep that is means the 
cylinder and power works fine.

Test Thumb Turn
Thumb Turn drives the deadbolt out and retracted manually. And it can 
be released automatically by turning the back handle. 
Please make sure the back handle and thumb turn works fine before 
closing the door otherwise it may cause problem that the lock can not 
be opened or closed from inside room.

2.Install

 

the

 

mortise

Punch

 

holes

 

on

 

the

 

door

.

User

 

prepare

30

mm dia hole drill bits + 

Electric

 

drill 

        

WARNING

For the safety,it is suggested strongly that you check 
the operation of the emergency key and back lever 
handle under the door in opening status

 

latch

retracted

4

Lock Installation

Содержание Zigbee

Страница 1: ...Wireless Network System 2 4G Zigbee ...

Страница 2: ... Congratulations on your selection of the Hotel Lock System This is a solution that carry out a modern efficient and safe management of the rooms in hotel resorts apartment school lodge office hospitals cruise ship by application of hardware and software Before using the instrument be sure to carefully read through the instructions contained in this manual Please keep all information for future re...

Страница 3: ...1 Strike 12 Strike box 13 Power Connector 14 PCB Connector 15 Thumb turn 16 Thumb turn cover 17 Battery box 18 Connector to mortise 19 Connector of Power 20 Connector to reader 21 Battery cover A B Lever handing top view front view left hand lever right hand lever 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 arrow horizontal 21 18 19 20 2 Lock Structure Installation ...

Страница 4: ...iliary bolt Deadbolt Thumb knob spindle Cylinder hole Reader Battery box back panel front panel Thumb knob Cylinder cover This is a standard right lever mortise The left mortise in reverse case Battery pack is hide in mortise for mortise model K1L Mortise K3S is the one of several different mortise of all model locks BACK SIDE Connect to battery pack Connect to PCB board FRONT SIDE ROOM OUTSIDE AN...

Страница 5: ...draw around the faceplate Remove the mortise and score the outline with a stanley knife to avoiding splitting when chiseling Chisel a rebate to allow the latch to fit flush to the surface Fix the mortise with the screws with the bevel towards the door frame 3 Fix the cylinder Insert the cylinder from front and tight the screws from back by using the inner hexagon screw driver 4 Install front and b...

Страница 6: ...Area Networks LR WPANs such as wireless light switches with lamps electrical meters with in home displays consumer electronics equipment via shot range radio needing low rates of data transfer Zigbee is targeted at radio frequency RF applications that require a low data rate long battery life and secure net working Model LA173 Dimension 89X89X33cm Power DC 9V Working current 100mA Wireless Technol...

Страница 7: ...ID must differ Neighbouring ID m ustdiffer c o r r i d o r There are only 4 type channel La173 ID XXXX0F01 Channel ID It is strongly recommended that LA173 be placed in a proper position according to their IDs The same channel ID La173 should not be put in neighbouring position due to it may cause the data transfer jam especially in the same floor and neighbor floor 6 Wireless Node Location ...

Страница 8: ...Wireless Node X2 7 Wireless Node Location ...

Страница 9: ...per location 4 1 Login Operator SYSTEM Password 0 zero 1 Installation of Software Server a Install software Hotel Lock System and server Xentral from software CD b It is recommended that both of applications be installed NOT in disk C the system drive Xentral 3 Build Connection Run Xentral Xentral is a smal tool that make building connection Run it after installation for the first time then exit F...

Страница 10: ...ick OK 1 3 Encoder beep once and there comes a window show the hotel code read from Authorized card It is 881A0001 click OK here 1 4 Licence code update window jumped asking input licence code Fill in the licence code given by Xeeder and click Update Register successfully click OK Soft will off automatically again When next running it is a register version and you will see Registered on the head o...

Страница 11: ...to start add new IP section 6 In IP Setting menu click Add 4 Select Advenced 7 Fill in the new IP address as following rule Sample If IP of node LA17X is 192 168 1 201 Then add to PC new as 192 168 1 XXX New IP section added completed Same as LA17X node IP 192 168 1 XXX 8 Click Add ATTENTION a The above steps are significant b The aim is to set network segment c PC should have a segment same as no...

Страница 12: ...0200F11 MAC 00200F99 SAMPLE Initialization MAC address of lock Users should set an unique MAC address to each lock in hotel lock system software The MAC address is based on the ID of node which is connected with the lock Each node has an unique ID Please check the node case to find MAC 00201810 MAC 00201811 MAC 00201899 ID 00201801 MAC Configuration Rules 11 ...

Страница 13: ...uild all room information as following floor by floor and node by node MAC address accords to Node ID Select the correct node as planned Create all room information following is an example What can xeeder hotel lock knows the card in valid term or not Clock of lock Valid term still not effebtive Check in start time Due Check out ent time expiry 09 00 24 00 09 00 24 00 09 00 next day Lock Configura...

Страница 14: ...ells you there is some problem with your wireless network Connect Connect very well Lockvents ICON Each lock event will show by icon lively in the status block It shows noting when there is no lock events happen Opening Door is in opening Card It tells you door was opened by card Key It tells you door was opened by key Setting succeed Once you see it you already comlete initalization Status Block ...

Страница 15: ...ng timeat a time several minutes ahead of the real when you issue it in Hotel Lock System Then you can do floor by floor by changing a fresh Time card Setting card should be issued in Hotel Lock System It should be 1 pc for 1 room because it saves 1 room ID only We suggest you issue all rooms at one time and mark on each card room ID STEP 4 Activate clock STEP 5 Set room ID STEP 3 Set hotel code I...

Страница 16: ...Basic Action 15 ...

Страница 17: ...Make check in 16 ...

Страница 18: ...t and refused Dead bolt is on Refuse card Dead bolt is on Refuse card Recover unvoided the lost card OK Card s using term has not match Card is in future s date or already expiry or lock s clock is slow or lost Check card s begin and end time If of problem please renew the lock s clock by reading a fresh Time card Card read successfully and unlock able Card read successfully and unlock able Card r...

Страница 19: ...www xeederlock com 2006 2015 Xeeder Technology Co Limited All rights reserved Baoan Shenzhen China Tel 0086 755 83663830 Fax 0086 755 22635115 7x24 hours Email sales xeeder com ...

Отзывы: