background image

 

MOUNTING WITH SCREWS

 

 

 

 

In case of mounting modules directly to the construction XDISC S.A. advises to use M8 screws. 

MAINTENANCE OF PHOTOVOLTAIC MODULES ASOL-250P-WSR

 

Photovoltaic modules require very little maintenance with respect to their configuration, except for parts and 
the interior circuits of the cells and the connection welding insulated by layers of protective material.  

Maintenance covers the following processes: 

-

 

Periodic cleaning of the module. 

-

 

Visual inspection of possible internal deterioration of the water-tightness of the module. 

-

 

Control of the state of the electrical connections and wiring. 

-

 

Eventually, control of the electrical characteristics of the module. 

PERIODIC CLEANING OF THE MODULE 

The  dirt  accumulated  on  the  transparent  cover  of  the  module  reduces  its  performance  and  can  produce 
reverse effects similar to those produced by shading. The problem can become serious in the case of industrial 
waste or waste caused by birds. The intensity of the effects depends on the opaqueness of the residue. The 
layers of dust that reduce the intensity of the sun are not dangerous and the reduction in power is not usually 
very  significant.  The  regular  recurrence  of  the  cleaning  process  depends,  logically,  on  the  intensity  of  the 
process. Rainfall can help in many cases to reduce or eliminate the need to clean the modules. 
The cleaning in general should be done by the special trained staff, always trying to avoid the accumulation of 
the water on the module. It is not advisable to use pressure hoses under any circumstances.  

VISUAL INSPECTION  

The visual inspection is meant to detect possible failures, specifically: 

-

 

Possible breaks in the glass. 

Содержание ASOL-250P-WSR

Страница 1: ...MOUNTING INSTRUCTION for PHOTOVOLTAIC MODULES Type ASOL 250P WSR ...

Страница 2: ...UNDING 6 ELECTRICAL SPECIFICATIONS 6 By pass diode specifications 6 LOCATION SELECTION 6 MODULE TILT ANGLE 6 MOUNTING OF THE MODULES 7 Clips location 7 Mounting with screws 9 MAINTENANCE OF PHOTOVOLTAIC MODULES ASOL 250P WSR 9 Periodic cleaning of the module 9 Visual inspection 9 Connection and wiring controls 10 Manufacturer 10 ...

Страница 3: ...d professional manner Electrical work should be performed by a qualified electrician WARNING This photovoltaic module produces electricity when exposed to the sun or other light sources The electrical hazard from the voltage and current of a single module is low However the voltage increases as modules are connected in series and the available current increases as modules are connected in parallel...

Страница 4: ...uch the terminals with bare hands Use insulated tools when wiring to solar module terminals wear rubber gloves to eliminate shock or burn potential when wiring solar modules Regardless of whether you are working on a new or existing roof never allow the sheathing and metal parts to become wet Protect the sheathing and metal parts from rain during the installation Failure to do so may cause leaks W...

Страница 5: ...for components capacity of conductors size of fuses and size of control systems connected to the module output are determined multiply the values of short circuit current Isc and open circuit voltage Voc that are marked in ASOL 250P WSR series modules by the coefficient 1 25 Before installing your system contact local authorities to determine the necessary permit installation and inspection requir...

Страница 6: ...st Conditions rated power Accordingly when determining component ratings and capacities the module short circuit current at STC should be multiplied by 1 25 and a correction factor should be applied for the open circuit voltage An additional 1 25 multiplier for the short circuit current for a total of 1 56 for sizing conductors and fuses may be applicable depending on your local regulations BY PAS...

Страница 7: ... location RECOMENDED TILT ANGLES FOR A FIXED SYSTEM SITE LATITUDE IN DEGREES FIXED TILT ANGLE 0 to 15 15 15 to 25 SAME AS LATITUDE 25 to 30 LATITUDE 5 30 to 35 LATITUDE 10 35 to 40 LATITUDE 15 40 LATITUDE 20 MOUNTING OF THE MODULES CLIPS LOCATION XDISC S A recommends using typical aluminium clips designed for framed modules ASOL 250P WSR module mounting configurations must meet the following requi...

Страница 8: ...e mounted and must not cause any twist or stress to be placed on the module Modules should be secured to mounting structure using four aluminium at least 80 mm long module clips The retaining clips must each provide a minimum contact area of 10 mm x 80 mm The centre of mounting clips must be located on the long side of the module between 350 mm and 400 mm from the edge See following figure for all...

Страница 9: ...d on the transparent cover of the module reduces its performance and can produce reverse effects similar to those produced by shading The problem can become serious in the case of industrial waste or waste caused by birds The intensity of the effects depends on the opaqueness of the residue The layers of dust that reduce the intensity of the sun are not dangerous and the reduction in power is not ...

Страница 10: ... wiring Also check to be sure that mounting hardware is tight Loose connections will result in damage for array Do not touch live parts of cables and connectors Use appropriate safety equipment insulated tools insulating gloves etc when touching them Cover the front surface of the Module by an opaque or other material when repairing The ASOL 250P WSR modules when exposed to sunlight generate high ...

Отзывы: