28
X-pert Charger X90T
EN
End of charging
·
Data View Mode
M11
M12
M13
M14
M15
M16
M17
M18
BACK
SAVE
BACK
START
LiPo CHG Con
fi
rm
-Connect -
Input Vol ... OK
Mainport ... OK
Bala Port ... OK
TYPE
LiPo
CELLS
6S
CURR
2.2A
Set Charge Current
2.2 A
SAVE
BACK
START
TYPE
LiPo
CELLS
6S
CURR
2.2A
Set Battery type
LiPo
SAVE
BACK
START
TYPE
LiPo
CELLS
6S
CURR
2.2A
Number Of Cells
6 (s)
SAVE
BACK
START
GRAPH
DATA
STOP
CELL
Input Volt 12.51V
End Volt. 25.20V
CAPA Cut-Off 10.0Ah
Safety Timer 240min
Temp.Cut-Off 60
℃
:
:
:
:
:
GRAPH
DATA
STOP
CELL
Voltage 24.76V
Current 2.16A
Capacity 7mAh
Int Temp. 33
℃
Ext Temp. 29
℃
:
:
:
:
:
GRAPH
DATA
STOP
CYCLE
C1 : 9 D1 : 0mAh
C2 : 0 D2 : 0mAh
C3 : 0 D3 : 0mAh
C4 : 0 D4 : 0mAh
C5 : 0 D5 : 0mAh
GRAPH
DATA
STOP
CELL
1) 4.124
2) 4.130
3) 4.113
4) 4.122
5) 4.135
6) 4.117
GRAPH
STOP
CELL
LiPo BCHG 6S 00:00:45
24.75V 00:01:41
BACK
Nixx Cycle record
LiPo BCHG 6S 00:00:45
LiPo BCHG 6S 00:00:20
Select
battery type (TYPE)
and
number of cells (CELLS)
Set
number of cells (CELLS)
with
the arrow keys
increase value
decrease value
Set
charging current
(CURR)
with
the arrow keys
increase value
decrease value
Note:
the charger will set the charge current
according to a rate of 1C automatically when
you set the capacity of the battery pack. If the
battery pack allows you to charge with a
higher rate, you can set the current CURR
higher.
WARNING:
check the battery sticker to
make sure the battery is designed for a
higher charging current -
fire hazard!
SAVE
your settings.
When charging this battery
again, you may select the
battery memory on the
Main screen.
Please see chapter
Charging process.
or
press START.
The battery
will be charged without saving
the charging parameters.
Charging monitor
Voltage:
Current:
Capacity:
Int. Temp.:
Ext. Temp.:
current battery voltage
current charging current
charging capacity
Charger internal temperature
is an external temperature sensor connected, the
temperature is shown here
DATA monitor
Current input voltage
Battery cut-off voltage
Max. capacity
Safety timer
Battery cut-off temperature
GRAPH
graphical display of the
charging voltage
Press
BACK
to go back to the
charging monitor
CELL
graphical and numerical display
of the cell voltages
NiXX CYCLE
numerical display of the cycle
data
(NiXX mode only)
End of charging
• If the battery is fully charged,
FULL
appears in the display, as well as an acoustic signal sounds for about
10 seconds.
•
NOTE:
if the charging process is terminated by safety timer, the display will show
STOP
. Check the
charging parameters and start the charging process again if necessary.
• When charging is complete, the battery can be disconnected from the charger. If the charger is no longer
needed, it should be disconnected from the power supply.
Data View Mode - single cell voltage/internal resistance
here you can check the single cell voltage and internal resistance of the connected battery pack.
STOP
1) 4.108
2) 4.097
3) 4.103
4) 4.104
5) 4.102
6) 4.108
00.00.09
VOL
LiPo
BACK
BALA
1) 08m
Ω
2) 15m
Ω
3) 06m
Ω
4) 09m
Ω
5) 14m
Ω
6) 04m
Ω
IR
LiPo
BACK
BALA
1) 4.110
2) 4.097
3) 4.103
4) 4.105
5) 4.103
6) 4.109
LiPo
VOL
BALA
Select battery type
(LiPo / LiIo / LiFe)
Select single cell voltage
VOL
or internal resistance
IR
.
The balancer function
BALA
is recommended for an
unbalanced or old battery.
Press
BALA
to start.
Содержание X-PERT X90T
Страница 17: ...17 X pert Charger X90T DE ...
Страница 30: ...30 X pert Charger X90T EN Error messages and their meanings Error messages and their meanings ...
Страница 50: ...50 X pert Charger X90T ...
Страница 51: ...51 X pert Charger X90T ...