background image

 

User Manual 

Version: 1.7

 

 

 

 

Page: 5 / 47

 

3

 

Safety Guide  

The  XBody  Newave  is  intended  as  a  training  and  exercise  appliance  for  muscle 
conditioning  in  conjunction  with  the  XBody  Training®  functioning  on  the  basis  of  electronic 
stimulations applied to various muscle groups through the use of electrodes contained in the XBody 
Training Suit. Follow the instructions in this manual to assure proper training and safety operation to 
the user. The safety regulations related to the Training can be found in this section.  Be aware that 
improper use of this equipment can cause injury. XBody Hungary LLC does not take the responsibility 
where user negligence or improper use of the equipment has occurred. 

3.1

 

Contraindications - Who should not use the XBody Newave 

The usage of XBody Newave is contraindicated in the following conditions: 

 

If you are equipped with a cardiac pacemaker, defibrillator, or other implanted metallic or 
electronic device. 

 

If you are epileptic or you have any nervous system disorder. 

 

If you have recently been victim of an acute trauma (less than 6 months). 

 

If you have recently been subject to a surgical procedure (less than 6 months). 

 

If you are pregnant. 

 

If you have blood flow deficiency or critical ischemia in your lower limbs. 

 

If you have an abdominal or inguinal hernia. 

 

If you suffer from cancer or cancerous lesions. 

 

If you have any suspected or diagnosed cardiac problems or diseases. 

 

If you have severe hemophilia. 

 

If you have thrombosis tendencies (thrombophilia, blood clots issues, etc.). 

 

If you have any acute or chronic infections. 

 

If you have any joint showing a decrease in its range of motion. 

 

If you have painful or afflicted joints. 

 

If you have atrophied or painful muscles. 

 

If you have muscle spasms. 

 

If you need muscle reeducation. 

 

If you have fever. 

 

If you are consuming drugs or alcohol regularly. 

3.2

 

What should never be done with the XBody Newave 

 

Never use it while driving, operating machinery or during any activity in which involuntary 
muscle contractions may put the user at risk of injury. 

 

Never use it in the bath or shower. 

 

Never use it in any humid atmosphere like sauna, bathroom or around a swimming pool. 

3.3

 

Usage is contraindicated for the following applications 

 

To prevent or rehabilitate muscle disorders. 

 

To prevent venous thrombosis. 

 

To maintain or increase range of motion. 

Содержание Newave

Страница 1: ...USER MANUAL...

Страница 2: ...ining intentions 7 3 6 Adverse Reactions 8 4 Preparing for the first use 9 4 1 Preparation of the machine for the first use 9 4 2 Cables 12 5 Using the software 13 5 1 Overview of the windows of the G...

Страница 3: ...portant information about your XBody Newave and its accessories Before using the machine please make sure that you have familiarized yourself with the contents of this manual by reading it carefully I...

Страница 4: ...mpulses allow the triggering of action potentials on motoneurones of motor nerves excitations These excitations of motoneurones are transmitted to the muscle fibers via the motor endplate where they g...

Страница 5: ...ard Spiral cable User Manual XBody Newave standard machine assembled XBody Newave port machine assembled Spiral cable The products shown on the pictures are illustrations similar to the products order...

Страница 6: ...an 6 months If you have recently been subject to a surgical procedure less than 6 months If you are pregnant If you have blood flow deficiency or critical ischemia in your lower limbs If you have an a...

Страница 7: ...should be kept out of the reach of children People under the age of 16 are not allowed to use the machine People with mental deficit can only use the machine with supervision This device should only b...

Страница 8: ...training sessions The trainer must inform the client of the importance of pre contracting the targeted muscles At high intensity stimulation the pre contraction voluntary contraction can help to avoid...

Страница 9: ...would like to turn off the machine during training first push the stop button and then unplug the clip which connects you and the machine 3 7 Adverse Reactions Headache can be felt if the training in...

Страница 10: ...e reviewed at any time by accessing www xbodyworld com set up The serial number of the device has to be given prior having access to the content Available languages are Hungarian English and German In...

Страница 11: ...iant The assembled machine with the port leg For the first step the leg should be placed on solid ground right after unpacking The head element is installed on the leg as shown in the figure above The...

Страница 12: ...g the training Placing the head on the leg On the back side of the head you can find an On Off button a USB port and a parallel port Only an XBody USB drive can be plugged into the device which is pro...

Страница 13: ...of the training environment to assure best start up responses to the introduction of electrical power 4 2 Cables The spiral cable is manufactured by XBody Hungary LLC and is uniquely identified It con...

Страница 14: ...ious signs of wear and damage Use only your fingers to control the software The screen must not be used with sharp objects If the screen is damaged it should be sent for repair For efficient operation...

Страница 15: ...ware starts with the Login screen window which can be seen below In order to access the functions of the software a successful login is required The machine can be used in administrator or training mo...

Страница 16: ...ove on to the next screen by pressing the OK button If the given password is wrong please check if you have chosen the appropriate user and give the corresponding password again At the bottom of this...

Страница 17: ...the Administrator can be modified here too Edit pass types With this option you can create new pass types edit or delete existing ones Statistics With this option you can get an overview of the traini...

Страница 18: ...t side a Plus button makes it possible to add a new trainer For adding a new trainer a name and an e mail address is required Note that the e mail address must be a syntactically valid e mail address...

Страница 19: ...n the left side An existing trainer can be edited by pressing the Edit button During editing a trainer can be deleted by pressing the Delete button The window can be left by pressing the Back button a...

Страница 20: ...e to add a new trainer For a valid pass a name the number of trainings covered in the pass the number of days that the pass is valid for and a suggested price is required If a client does not have a v...

Страница 21: ...have a look at on their statistics If the administrator selects the Administrator user the total statistics is shown Statistics are given on a daily weekly monthly basis and a total is calculated as w...

Страница 22: ...er confirmation Resetting means that the statistics are wiped out and they are calculated later on from the time of resetting only Exporting can be performed onto an USB stick which can be plugged in...

Страница 23: ...rmation about the product and a reset button that sets the machine back to its factory state The administrator can also decide whether the presentation user should be enabled for each trainer or not T...

Страница 24: ...ed to buy a pass for training and don t need to store client data Please use the Presentation mode only if it is necessary The regular way of training is that after you login with a trainer a client i...

Страница 25: ...new customer the name a valid e mail address as described before and the birth date should be added To type in the data the virtual keyboard can be opened by tapping one of the input fields Additiona...

Страница 26: ...e sizes of the different clothing items can be given The previous page can be accessed by pressing the Left arrow button while more clothing sizes can be specified on the next page An existing client...

Страница 27: ...begin directly since it is an opportunity to free trainings for presentation purposes For any registered customers first a new pass should be bought among one of the previously registered pass types...

Страница 28: ...training Every program has 10 independent stimulation channels for specific stimulation of predefined major muscle groups Stimulation intensity can be varied on each channel anytime The muscle groups...

Страница 29: ...r buttons that can be used to select the appropriate training program The window shows the net training time of the current training session The window can be left by pressing the Back button at the b...

Страница 30: ...the green Start button in the center above the Slider After the training is started the training a Master regulator appears starting at 0 and the current state of the training can be seen in the midd...

Страница 31: ...ike to train with multiple programs it is possible to navigate back to the Program selector window and choose another program In this case the training intensities are stored and moved between program...

Страница 32: ...ond It can be set between 1 100 Hertz The assured frequency of the stimulation on the electrodes is within a 5 threshold of the preset value Impulse depth This parameter gives the physical length of o...

Страница 33: ...ner is trying to set the frequency above 10 Hz a warning message is displayed If the action was unintentional this protects the client by declining the action on the popup window If the action is inte...

Страница 34: ...thus continuous impulse cannot be set in this program Also the impulse frequency is constrained between 50 85 Hertz The Cardiovascular program has the following stimulation parameters by default In th...

Страница 35: ...indow can be left by pressing the Back button at the bottom left corner of the screen In the Video program first a Video selector window appears A video can be selected by clicking on its icon In the...

Страница 36: ...ideo is selected appears the Video training window This window is very similar to a regular Training window but there are video control buttons on the bottom of the window To begin the training the Pl...

Страница 37: ...ensity parameters of the electrodes are set This way the trainee can focus better on the exercise itself Pressing the Full screen button again takes back to the small view with the stimulation control...

Страница 38: ...dification of any part of the device is allowed Maintenance can only be done by the manufacturer Please call the helpdesk if maintenance is necessary It is strictly prohibited to do any maintenance on...

Страница 39: ...above did not help to make the stimulation be felt do the following Put the suit on the ground Connect the optional cable also Connect the suit cable to the device with the spiral cable Switch on the...

Страница 40: ...calculations on the maximal outputs of the XBody Nevawe Med machine This section also references the requirements of the standard according to essential performance and the referencing against their i...

Страница 41: ...ing section The values are 100 accurate expect the frequency which has 5 accuracy The measurement below is done by using the Manual settings program with the parameters specified below Name Value Impu...

Страница 42: ...rol of intensity This means that each channel has a regulator between 0 100 with 1 step and there is a master regulator that has a multiplicative effect on the channels which is also allowed 0 100 wit...

Страница 43: ...the date of buying and the serial number Please wrap the product as a fragile one Damage caused during the delivery is the sender s responsibility Send the package to the following address XBody Hung...

Страница 44: ...ludes the price of repairing of the machines Warranty period for the device is 24 months The damages of the accessories do not mean the replacement of the machine automatically Tearing or damaging the...

Страница 45: ...apply to it Old machines must not be thrown among the domestic waste Please follow the rules for the waste collection in that area or get into contact with the helpdesk of XBody we take over the waste...

Страница 46: ...30 mm Size port leg 400 x 240 x 160 mm Weight port leg 2 7 kg Weight standard leg 14 6 kg Total size head with standard leg 400 x 530 x 1270 mm Total size head with port leg 400 x 240 x 430 mm Power s...

Страница 47: ...0 s 1 1 s Width of pulse 50 s step by step 50 s 400 s Length of the program 1 min step by step 5 min 15 min 5 min step by step 15 min 45 min Mode Symmetric biphasic Number of channels 10 channels iso...

Отзывы: