15
reflect and cause interference. If a splitter is used, terminate each branch of the link.
This fixtures introduced before 1997 have reversed polarity data sockets (pin 2 hot
and pin 3 cold). The socket polarity is labelled. Use a phase-reversing cable between
any device with reversed polarity.
8. AC Power Supply
8.1
Fuses
The fixture is equipped with auto-switching power supply that automatically adjusts to
any 50-60Hz AC power source from 200-240 Volts. The fixture is protected by one 2 A
blow primary fuse (φ5x20).
8.2
Power connection
You may need to install a cord cap that fits your supply on the power cable. A 3-prong
grounding-type plug must be installed following the manufacturer’s instructions. The
table shows some possible pin identification schemes; if the pins are not clearly identified,
or if you have any doubts about proper installation, consult a qualified electrician.
To apply power, set the power switch on the base to the “On” position.
8.3
Replace Power Cable
Notice:
For protection from electric shock, the fixture must be earthed!