Step 6: Connecting Loads
M370046-01
2-11
2
Inductive Loads and Batteries
Selecting
Diodes
The diode must have a voltage rating at least 20% greater than the power
supply's output voltage and have a current rating greater than or equal to
the power supply's output rating. Connect the cathode to the positive
output and the anode to the return.
Where positive load transients such as back EMF from a motor may
ocAMPS, connect a Transient Voltage Suppressor (TVS) or a varistor
across the output to protect the power supply. The breakdown voltage
rating for the TVS or varistor must be approximately 10% higher than the
rated supply output.
For a detailed Application Note, please go to:
www.programmablepower.com and click SUPPORT.
CAUTION
The XTR power supply requires freewheeling and blocking diodes across the
output while driving inductive loads or batteries to protect the power supply from
damage caused by power being fed back into the supply and from high voltage
transients.
Figure 2-2
Diode Placement
Содержание XTR 850 Watt
Страница 2: ......
Страница 3: ...XTR 850 Watt Series Programmable DC Power Supply firmware v1 09 and below Operating Manual...
Страница 6: ......
Страница 18: ...xvi...
Страница 30: ...1 8...
Страница 52: ...Local Operation 3 8 M370046 01 Figure 3 3 Front Panel Menu System...
Страница 82: ...Local Operation 3 38 M370046 01 The SCPI command s for these instructions are SYSTem channel s REMote STATe...
Страница 86: ...Local Operation 3 42 M370046 01 Figure 3 5 Split Supply Operation V V Common Power Supply Power Supply Load...
Страница 126: ...Analog Programming APG and Isolated Analog Programming ISOL 4 34 M370046 01...
Страница 198: ...5 72...
Страница 234: ...A 36...
Страница 284: ...IX 4...
Страница 285: ......