![Xantrex XTR 850 Watt Скачать руководство пользователя страница 113](http://html1.mh-extra.com/html/xantrex/xtr-850-watt/xtr-850-watt_operating-manual_3458198113.webp)
Isolated Analog Programming Mode (ISOL)
M370046-01
4-21
4
Table 4-4
AUX Output and ISOL Connector Pins and Functions J3
PIn
Reference
Function
J3.1
AUX_ON_OFF
Auxiliary enable/disable
J3.2
COM_ISOLATED
Isolated Common (Isolated from Main Output and Communication.
Return wire for +5 V, +15 V Auxiliary Voltage.
J3.3
IS_VOL_PR_VOL
Isolated Analog Voltage Programming Input
J3.4
IS_VOL_PR_CUR
Isolated Analog Current Programming Input
J3.5
IS_MON_VOL
1
1.Important: Isolated monitor lines are only valid when Isolated analog programming modes are
used for the respective voltage and current control. If local control, digital control or non-iso-
lated APG is used, the non-isolated monitor lines should be used as the isolated monitor lines
will not accurately reflect the output state of the power supply.
Isolated Voltage Monitor. Scaled to the value of the Voltage Analog
Programming Level.
J3.6
COM_ISOLATED
Isolated Common (Isolated from Main Output and Communication.
Return wire for control signals, monitoring and programming.
J3.7
ISO_CUR_RES_PR
Isolated Current Resistive Programming
J3.8
ISO_VOL_RES_PR
Isolated Voltage Resistive Programming
J3.9
+AUX 1
2
+5 V Isolated Output
J3.10
IS_MON_CUR
1
Isolated Current Monitor. Scaled to the value of the Voltage Analog
Programming Level.
J3.11
+AUX 2
2
2.Use unshielded cable up to 9.84 feet (3 m) length with high-density D-Sub type connector and
a ferrite bead (Fair-Rite part number 0443164251).
+15 V Isolated Output
J3.12
SD
Shutdown. Input to power supply to disable output. This input has
user selectable negative logic operation via front panel or remote
digital input/output.
J3.13
PS_GOOD
PS_GOOD. Power supply output enabled.
J3.14
INTER_LOCK 1
Interlock. Dry contact type. Shorting pins J3.14 and J3.15 while the
interlock functionality is enabled, will enable the output of the
power supply.
J3.15
INTER_LOCK 2
Interlock
Содержание XTR 850 Watt
Страница 2: ......
Страница 3: ...XTR 850 Watt Series Programmable DC Power Supply firmware v1 09 and below Operating Manual...
Страница 6: ......
Страница 18: ...xvi...
Страница 30: ...1 8...
Страница 52: ...Local Operation 3 8 M370046 01 Figure 3 3 Front Panel Menu System...
Страница 82: ...Local Operation 3 38 M370046 01 The SCPI command s for these instructions are SYSTem channel s REMote STATe...
Страница 86: ...Local Operation 3 42 M370046 01 Figure 3 5 Split Supply Operation V V Common Power Supply Power Supply Load...
Страница 126: ...Analog Programming APG and Isolated Analog Programming ISOL 4 34 M370046 01...
Страница 198: ...5 72...
Страница 234: ...A 36...
Страница 284: ...IX 4...
Страница 285: ......