Symptom
The AC load runs for more than one minute,
the alarm sounds, and the
light comes on. The
inverter is warm or hot to touch. The alarm may sound.
The AC load will not operate; no inverter lights are on.
Symptom
The inverter has been connected to the 12 volt
battery and the battery is charged, but the inverter does not
work.
The battery voltage is
excessive.
Check the charging system.
Possible cause
Suggested remedy
Poor ventilation or a high-
temperature environment has
caused the
inverter
to
overheat.
Ensure that ventilation is not
restricted around the inverter.
The inverter will turn on again
automatically when it has
cooled sufficiently.
Possible cause
Suggested remedy
The inverter could have been
connected with reverse DC
input polarity.
The inverter has probably been
damaged. Have it repaired.
Damage caused by reverse
polarity is not covered by the
warranty. Instructions for
returning the inverter are on
page 31.
Possible cause
Suggested remedy