16
6. Remove the nuts from the DC terminals on the inverter.
7. Place the red ring connector on the red (po) DC
terminal on the inverter, and then screw the red nut on
until it is snug. Do not over tighten.
8. Fasten the positive terminal (red wire) to the positive
battery post.
9. Fasten the negative terminal (black wire) to the
negative battery post.
10. Place the black ring connector on the black (negative –)
DC terminal on the inverter, and then screw the black
nut on until it is snug. Do not over tighten.
11. Turn on the in-line switch.
12. Turn on the inverter’s On/Standby switch. The green
PWR
light comes on, and AC power is available at the
outlet.
Disconnecting the Battery
•
Before you disconnect the battery, turn off the AC load,
and then turn off the in-line switch.
Replacing the In-Line Fuse
•
If you need to replace the in-line fuse (Figure 6), turn
off the in-line switch to disconnect the DC power.