15
7 Inverter Operation
1.
When properly connected to a 12 V outlet or
battery, turning the inverter switch ON, will
illuminate the green POWER light, and deliver
AC power to the outlet(s).
2.
Plug the AC product(s) you wish to operate into
the AC outlet(s) and switch them on, one at a
time.
3.
As the battery is used, voltage begins to fall.
When the XPower inverter senses that the voltage
at its DC input has dropped to 11 V, an audible
alarm sounds. This allows time for computers or
other sensitive devices to be shut down.
4.
If the audible alarm is ignored, the XPower
inverter will automatically shut down when the
battery voltage drops to 10.5 V. This prevents the
battery from being damaged. After auto
shutdown, the red FAULT light illuminates.