Installation
975-0136-01-01
9
Connector Requirements
Different types of connectors are required to install the Xanbus-enabled
devices on the network cable.
RJ45 connector
The network cable uses modular RJ45 connectors, as shown in Figure 6.
The connector is suitable for cost-sensitive applications and is easily
installed by an end user. The RJ45 connector should be a modular plug, 8-
position, 8-contact for round, stranded, unshielded cable.
Network Power Supply
In a Xanbus System, the power sources must provide sufficient power for
all of the Xanbus-enabled devices.
Power supply
The network must have at least one device with a power supply to run the
network. The total network current supplied by all the power-sourcing
devices must be greater than or equal to the total current drawn by the
power consuming devices.
For example, in a system with an inverter/charger, an interface panel and
an Automatic Generator Start, the inverter/charger is a power-sourcing
device capable of providing 800 mA at 15 VDC while the two other
devices each consume a maximum of 200 mA for a total maximum
consumption of 400 mA. In this example, the network is properly
configured from a power perspective because the power source is capable
of providing more current than is needed: 800 mA
≥
400 mA.
Figure 6
RJ45 Connector
Important:
All networks, regardless of type, require a device that powers the
network. Typically, this is your inverter/charger.
Note:
See your Xanbus device guides to determine how much power each
device consumes or supplies.
Содержание Xanbus System
Страница 1: ...Xanbus System Installation Guide ...
Страница 2: ......
Страница 3: ...Xanbus System Installation Guide ...
Страница 8: ...vi ...
Страница 10: ...viii ...
Страница 11: ...Installation The Installation Guide provides detailed information for planning and installing a Xanbus System ...
Страница 34: ...24 ...
Страница 35: ......