Local Operation
3-20
M370078-01
Clearing Automatic Alarms
Some alarms will clear automatically when the condition that caused the
alarm is no longer present. When an alarm automatically clears, the
output voltage and current displays will return to normal, but the ALARM
LED will remain illuminated to indicate that an alarm has occurred. If an
automatic alarm is triggered, the normal alarm clearing procedure still
applies.
To clear the ALARM LED after an automatic alarm has cleared, use
one of the following methods:
•
Send the SCPI Clear Alarm command.
•
Press the OUTPUT ENABLE Main button to reenable the output.
The ALARM LED will no longer be illuminated.
For example, if one of the fans in the XG was temporarily blocked,
causing a Fan alarm,
then the blockage was cleared and the fans restarted,
the alarm would clear. The output voltage and current displays would be
in normal mode, but the ALARM LED would be illuminated. See “Front
Panel ALARM LED” on page 3–20 for information on other events that
affect the ALARM LED.
Alarms status is tracked in the SCPI status registers. For more details on
how and where the alarms are tracked, see “Standard SCPI Register
Structure” on page 5–34
.
Front Panel ALARM LED
The Alarm LED will illuminate due to one or more of the following
events occurring:
•
OTP has been tripped.
•
A fan has stopped.
•
OVP has tripped.
•
OCP has tripped.
•
UVP has tripped
•
Interlock is open circuit.
•
AC power falls out of range.
•
Foldback has tripped.
•
Persistent storage checksum is wrong (Flash Fail alarm).
•
Internal malfunction of power supply.
•
Any alarm has tripped and been cleared automatically.
The alarm LED will remain illuminated until the alarm is manually
cleared (see “Clearing Triggered and Manual Alarms” on page 3–19) or
by turning the main output on if the alarm has automatically been cleared.
Содержание Watt Series Programmable DC Power Supply XG...
Страница 2: ......
Страница 3: ...XG 850 Watt Series Programmable DC Power Supply Operating Manual...
Страница 6: ......
Страница 18: ...xvi...
Страница 30: ...1 8...
Страница 52: ...Local Operation 3 8 M370078 01 Figure 3 3 Front Panel Menu System...
Страница 82: ...Local Operation 3 38 M370078 01 The SCPI command s for these instructions are SYSTem channel s REMote STATe...
Страница 86: ...Local Operation 3 42 M370078 01 Figure 3 5 Split Supply Operation V V Common Power Supply Power Supply Load...
Страница 126: ...Analog Programming APG and Isolated Analog Programming ISOL 4 34 M370078 01...
Страница 198: ...5 72...
Страница 262: ...A 36...
Страница 284: ...IX 4...
Страница 285: ......