Default Settings
6
Freedom XC PRO Owner's Guide
Default Settings
Table 1 lists the default settings for the Freedom XC PRO
system.
You may record your settings in the right-hand column after you
have configured the Freedom XC PRO.
Program
Item
Default Setting
Setting
01
Inverter ignition
control
Off
Off
02
Low battery
cutoff (LBCO)
voltage
10.5 volts DC
10.5
03
LBCO shutdown
delay timer
300 seconds
300
04
LBCO recovery
voltage
13.1 volts DC
13.1
05
Power save time
25 hours
25
06
Load sensing
Disabled
dis
07
Inverter output
frequency
60 Hz
60
Table 1 Freedom XC PRO Default Values
Program
Item
Default Setting
Setting
08
Inverter output
voltage
120 volts AC
120
09
Inverter power
limit Freedom XC
PRO 2000
2 kW
2
Freedom XC
PRO 3000
3 kW
3
10
Inverter power
limit timer
300 seconds
300
11
Transfer mode
Appliance
APL
12
Utility AC under-
voltage level
90 volts AC
90
13
Inverter fault
recovery
Manual
man
14
Audible alarm
On
On
20
Battery type
Flooded
Fld
21
Battery
temperature
Hot
Hot
22
Custom
absorption
voltage
14.4 volts DC
14.4