Operating Limits
975-0767-01-01
77
Input Voltage
The allowable Freedom X 1200 input battery voltage ranges are
shown in the following table:
Operating
Condition
Battery
Voltage
Comment
Full
Operating
Range
LBCO –
16.5 V
Assuming the battery is full, the
inverter will operate until battery
voltage goes past below LBCO
c
and LBCO Shutdown delay
timer
d
.
Low
Voltage
Recovery
< LBCO+0.5 V
Inverter is able to recover and
continue to operate.
Table 11 Input battery voltage range
c
To set LBCO, see
Adjusting Feature Settings in Configuration Mode on page 1
.
d
To set LBCO Shutdown Delay Timer, see
Operating
Condition
Battery
Voltage
Comment
Low
Voltage
Shutdown
< LBCO
The buzzer sounds a single 1 s
low battery alarm beep and the
LCD screen shows error code
E01
. After LBCO Shutdown
delay timer runs out, the unit
shuts down inverter output. The
buzzer stops beeping and the
LCD screen shows error code
E01
.
Instant Low
Voltage
Shutdown
< 10.2 V
After 2 s below the limit, the unit
shuts down inverter output
completely. LCD screen turns
off completely.