Display Panel
975-0390-01-01
21
Display Panel
FREEDOM HF
Input Voltage(V)
Select
STATUS
Battery
Fault
Utility
Input Current (A)
Output Power (kW)
1
3
2
4
Figure 9 Display Panel (All Models)
Item
Description
1
Inverter Power button
is the main unit switch that turns the
Freedom HF’s inverter function ON or OFF.
2
Three-digit LED display screen
shows status information and
fault codes.
3
Status LED
indicates the mode of operation with a three-color LED.
4
Select button
changes status information displayed on the display
screen.
IMPORTANT
: See
Display Panel Operation on page 29
for detailed information on operating the panel’s
buttons
Remote and Power Module Panel
1
2
a b c
Figure 10 Remote and Power Module Panel (Freedom HF 1055
EMS,1800 EMS)
Item
Description
1
Remote jack is used for connecting the Display panel that ships with
the Freedom HF 1055 EMS and 1800 EMS. Each shipment comes
with a 25-foot communications cable as well.
2
Power module has one fuse and three contacts for wires that
connect to:
a. an auxiliary 12-volt DC OUT terminal,
b. an Ignition Control terminal, and
c. a Disable terminal.
NOTE
: The Ignition Control and Disable terminals are connected by a jumper wire that acts to
disable ignition control. Removing the jumper wire will enable ignition control.
For instructions on how to enable or disable Ignition Control, see
the Installation Guide.
Содержание Freedom HF
Страница 57: ...This page is intentionally left blank 2 ...