Figure 13
Equalize Charging
Time
Time
Absorption Voltage
Equalize Voltage
Max Absorb Time - Dflt 3 hrs
Absorption Exit Current
Threshold = 2% of
programmed AH capacity
10% of charge current
Equalize mode
Custom Charge
Equalize Stage
Absorption Stage
Bulk Stage
Bulk Voltage
Battery
Current
Battery
Voltage
10 A
Equalize Timer
1hr fixed
default 6 hrs
975-0784-01-01
57
Operating in Grid Mode
Custom Battery Settings Menu
To avoid damaging your batteries during charging or equalization,
consult your battery manufacturer and associated documentation before
setting a custom battery type.
Custom battery type can be selected by the setting number 20 (see
“Settings” on page 46). After the custom battery is selected, you can
then adjust the value of custom absorption (setting number 22) and
custom float (setting number 23) accordingly.
NOTICE
EQUIPMENT DAMAGE
Failure to follow these instructions can damage the unit and/or
damage other equipment.
Freedom XC Series INV-CHG Owners Guide.book Page 57 Wednesday, June 7, 2017 3:13 PM
Содержание 817-1050
Страница 2: ...Freedom XC Series INV CHG Owners Guide book Page ii Wednesday June 7 2017 3 13 PM...
Страница 12: ...Freedom XC Series INV CHG Owners Guide book Page x Wednesday June 7 2017 3 13 PM...
Страница 14: ...Freedom XC Series INV CHG Owners Guide book Page ii Wednesday June 7 2017 3 13 PM...
Страница 22: ...Freedom XC Series INV CHG Owners Guide book Page 8 Wednesday June 7 2017 3 13 PM...
Страница 52: ...Freedom XC Series INV CHG Owners Guide book Page 38 Wednesday June 7 2017 3 13 PM...
Страница 76: ...Freedom XC Series INV CHG Owners Guide book Page 62 Wednesday June 7 2017 3 13 PM...
Страница 88: ...Freedom XC Series INV CHG Owners Guide book Page 74 Wednesday June 7 2017 3 13 PM...
Страница 89: ...Freedom XC Series INV CHG Owners Guide book Page i Wednesday June 7 2017 3 13 PM...