background image

2

SR21

Fig. 2  

The RC68 Programmer

RC68+ PROGRAMMER / REMOTE CONTROL

The RC68+ (and RC68) Programmer (available separately) contains
all the commands necessary to operate the SR21.

• You will need it to program universal learning devices such as the

Xantech URC series learning remote, the Xantech Smart Pads, the
590 Programmable Controller, the 710 Fone Link, etc., with com-
mands that operate the SR21.

• NOTE: The RC68+ codes operate several other Xantech models as

well, such as the RS41AV, RP41AV, ZPR68, etc. Therefore, only
the button descriptions that apply to the operation of the SR21
(Overlay "B") are listed below
.  All others should be ignored..

CAUTION:  While the RC68+ will operate as a separate remote
control, it is highly recommended it not be given to the final user for the
following reasons:

• Since it includes setable code groups, the user may inadvertently

alter the installer configurations.

• Also, since the user will require IR commands from other brands of

equipment to control the total system, in addition to those of the
SR21, all commands should be consolidated into one learning
device, for ease of use.

APPLICABLE RC68 BUTTON DESCRIPTIONS

1. Pair OFF Command.  This button activates the IR command that turns the internal relay of the SR21

to the OFF position (the A selection).

2. Pair ON Command.  This button activates the IR command that turns the internal relay of the SR21

to the ON position (the B selection).

3. TGL (toggle) Command.  The first press of this button turns the relay ON (the B selection) -the second

press turns it OFF (the A selection).

4. MMT (momentary) Command.  Pressing this button causes the SR21 relay to go ON (the B selection)

but stays ON only as long as the button is held down.  When released, the relay returns to the OFF
position (the A selection).

5. IR Emitter Lens.

CODE SUB-GROUP

The RC6+8 has 11 rows of 5 buttons each.  Each row, identified by the numbers 0 through 7 (see Fig. 2),
will execute the same set of 4 commands listed above, when selected by the CODE SUB-GROUP switch
on the SR21. This is useful to prevent mutual interaction in common IR systems when using more than one
SR21, or if CC12's are used with SR21's.

To change the CODE SUB-GROUP, simply rotate the CODE SUB-GROUP switch on the SR21 to the
number that corresponds to the desired row on the RC68+.  Remove and reapply power (after 20
seconds), then use the chosen row to execute the commands for that particular SR21.

NOTE:  No changes are needed on the RC68+!

6. Code Group Numbers.  The SR21 is also capable of being set to different basic code groups as well

as the sub-groups.

NOTE:  

When shipped from the factory, the SR21 is set to code group number 50.  Be sure to

set the RC68+ to the same number!

It may be necessary to change the SR21 to a  different code group if it is used in a common IR bus controlled
system with many SR21's, CC12'S, etc., to avoid mutual interaction.

5

OFF

ON

TGL

MMT

OFF

ON

TGL

MMT

OFF

ON

TGL

MMT

OFF

ON

TGL

MMT

OFF

ON

TGL

MMT

OFF

ON

TGL

MMT

OFF

ON

TGL

MMT

OFF

ON

TGL

MMT

0

2

3

4

5

6

1

7

80

48

10

90

01

00

C0

50

D0

41

40

A0

30

B0

21

20

E0

70

F0

61

60

88

18

98

09

08

A8

38

B8

29

28

E8

78

F8

69

68

C8

58

D8

49

E1

89

C9

A9

E9

71

19

59

39

79

F1

99

D9

B9

F9

Place the

"B" Overlay

on the RC68+

0

1

2

3

4

5

6

7

CODE

SUB-

GROUP

6

2

4

3

1

RC68+

B

Содержание SR21

Страница 1: ...lay contact rating provides 200 watts per channel capability into 8 Ohms All plug in connectors accept wire sizes from 24 to 12 gauge IR CONFIRM LED goes ON only when an RC68 IR command signal activates unit LED indicates A or B switching status Four RC68 IR commands permit OFF A ON B Pair Toggle A or B and Momentary operation of the switching relay IR activated ON condition ON B goes OFF Off A if...

Страница 2: ...turns it OFF the A selection 4 MMT momentary Command Pressing this button causes the SR21 relay to go ON the Bselection but stays ON only as long as the button is held down When released the relay returns to the OFF position the A selection 5 IR Emitter Lens CODE SUB GROUP The RC6 8 has 11 rows of 5 buttons each Each row identified by the numbers 0 through 7 see Fig 2 will execute the same set of ...

Страница 3: ...ns are the same as de scribed for Fig 3 To simplify the illustration otherpossiblesystemcom ponents are not shown in Fig 4 Again you would teach eitherthePairortheToggle commands from the RC68 into a learning remote to operate the SR21 along with your other system commands IR CONFIRM L L R R L L R R CODE SUB GROUP SR21 SPEAKER RELAY MODULE OFF A ON B R R L L 0 1 2 3 4 5 6 7 A B IR IN CI GND 12VDC ...

Страница 4: ... simple 2 way IR router to switch between two satellite receivers TV monitors etc Fig 5 is an example of how it can be used to improve the system shown in Fig 4 so that the IR control is automatically switched from one AM FM receiver to the other when the speaker outputs of the AM FM receivers are switched In this case be sure that both SR21 s are set to the same CODE SUB GROUP This ensures that t...

Отзывы: