Use unshielded, 3 conductor stranded wire, per the table below, when extending
the plug end of the IR Receiver Ribbon Cable. (4 conductor provides an extra
wire for back-up if one of the conductors gets damaged.)
IR WIRE LENGTH
IR WIRE GAUGE
UP TO 200’ (61m)
24 AWG
UP TO 600’ (183m)
22 AWG
UP TO 2000’ (610m)
20 AWG
UP TO 5000’ (1524m)
18 AWG
EN85
IR Receiver
White
Stripe
To 120 V AC
(unswitched)
781ERGPS
789-44
Connecting Block
REMOTE ROOM
MAIN ROOM
3-Terminal Block (not included)
3-Conductor
Extension Cable
(unshielded)
A/V Receiver
DVD
Satellite Receiver
283D Emitter
12VD
C
+12 VDC
GND
STATUS
IR IN
EMITTERS
IR
RCVR
789-44
CONNECTING BLOCK
®
IR OUT
+12V
GND
283D Emitter
283D Emitter
8” Ribbon Cable
(Do Not Add Length!)
6’ Ribbon Cable
(OK to Add Length)
Electronics Module
Hand Held
IR Remote
When adding wire length, confirm that the IR Signal, +12VDC and GND wires
are properly connected to both the IR Receiver and Connecting Block (Signal to
Signal; +12 to +12; GND to GND). Improper connection will affect performance
and possibly damage the IR Receiver. The EN85K Warranty does not cover this
type of damage.
Connections must be made as illustrated. To extend the Emitter wires to a more
distant location, you may splice in 2-conductor wire, in the wire gauges shown
above, as needed.
While it is possible to make wired connections without the Connecting Block, it
is not recommended. The Connecting Block reduces installation time, helps to
eliminate errors, allows easy troubleshooting and permits easy system upgrades
later, if needed.
Figure 16 -
3.5mm Stereo Mini Plug & Wire Pin-Out
Figure 17 -
Extending the Plug End of the IR Receiver Ribbon Cable