Discharge times
The following values apply to a UPoB with 12.5 F capacitance and 12 V input voltage.
Accuracy of values
Because the stated times are determined empirically, the values might devi-
ate under certain circumstances.
Output load
Bridging time
X
ORAYA
Minilogger V5 Advanced (
≈
0.7
A)
37 s
X
ORAYA
V5+ C20 (
≈
0.9
A)
28 s
X
ORAYA
Minilogger Z7 R8C4Ge2 (
≈
1
A)
26 s
X
ORAYA
V5
C20L4B12FAS
(
≈
1.6
A)
16 s
1 A
26 s
2 A
13 s
3 A
9 s
4 A
6 s
4.8 A
6 s
Output load
Trigger time
100 % 75 %
50 %
25 %
X
ORAYA
Minilogger V5 Advanced (
≈
0.7
A)
1 s
9 s
18 s
27 s
X
ORAYA
V5+ C20 (
≈
0.9
A)
1 s
7 s
14 s
21 s
X
ORAYA
Minilogger Z7 R8C4Ge2 (
≈
1
A)
1 s
6 s
13 s
19 s
X
ORAYA
V5
C20L4B12FAS
(
≈
1.6
A)
1 s
4 s
8 s
12 s
1 A
1 s
6 s
13 s
19 s
2 A
1 s
3 s
6 s
9 s
3 A
1 s
2 s
4 s
6 s
4 A
1 s
1 s
3 s
4 s
4.8 A
1 s
1 s
3 s
4 s