X2E UPoB Скачать руководство пользователя страница 1

 

UPoB 

Universal Power Bridge 

User Manual 

 

Version: 1.6 / April 2019

 

Содержание UPoB

Страница 1: ...UPoB Universal Power Bridge User Manual Version 1 6 April 2019...

Страница 2: ...Reproduction of this user manual even in part is only permitted with the approval of X2E GmbH Any infringement will result in liability for damages and may result in criminal prosecution All product n...

Страница 3: ...instructions 5 Product overview 6 Identification 6 Block diagram 7 Connections and controls 8 Installation 15 Mounting 15 Connecting 15 Firmware update 17 Cleaning 18 Repair 18 Disposal 18 Appendix 19...

Страница 4: ...is shut down safely The UPoB is designed for industrial areas and must not be used in residential areas You may only operate the UPoB within the scope of the technical specifications provided in this...

Страница 5: ...undamaged CAUTION Device damage due to vibrations dirt or liquids Excessive vibrations dirt or liquids may result in malfunction or destruction of the UPoB Avoid exposing the UPoB to excessive vibrati...

Страница 6: ...e contains information about device type serial number configuration date of manufacture last modification Configuration consists of three blocks product ID product variant hardware revision This user...

Страница 7: ...Capacitors Charge current Config Micro controller Trigger level Service Monitor 4 3 2 1 Normal mode Bridge mode COM Acoustic signals on mode change The UPoB indicates changes between normal mode and...

Страница 8: ...User Manual UPoB 8 Connections and controls Front view Back view...

Страница 9: ...in 11 0 V capacitors stop charging The capacitors get their maximum charging voltage of 10 0 V if the input voltage is 12 0 V or higher Mode changing thresholds Vin 10 0 V UPoB switches into bridge mo...

Страница 10: ...above 10 9 V Mode 3 mirrors the state of the input voltage at the output deactivates the voltage output if the input voltage drops below 10 0 V activates the voltage output if the input voltage rises...

Страница 11: ...s below the configured level the UPoB sends a trigger signal A trigger signal consists of an RS232 command to shut down a connected XORAYA data logger safely the data logger cannot be woken up by bus...

Страница 12: ...capacitors completely charged green blinking capacitors not charging and not discharging charge higher than 5 and lower than 98 blue capacitors charging charge higher than trigger level blue blinking...

Страница 13: ...nnected system can be damaged or destroyed due to the sud den voltage drop Shut the connected system down safely before pressing the reset button Discharge H This button discharges the capacitors The...

Страница 14: ...rm to the USB standard COM J The COM interface consists of an RS232 interface to communicate with a XORAYA data logger a CAN interface to send status messages a 5 V digital output a relay output with...

Страница 15: ...to improper connection Introducing the 4 mm plugs of the supplied power cable into low voltage sockets can be fatal Never introduce the 4 mm plug into low voltage sockets CAUTION Device damage due to...

Страница 16: ...uirements for the DC power supply A 12 V DC power supply must provide a current of 6 A This applies to a charge current of 0 5 A For a higher charge current a more powerful power supply is required Co...

Страница 17: ...Processor speed at least 1 GHz RAM at least 1 GB Execute the firmware update Connect the UPoB to the power supply see chapter Connecting Turn on the power supply Make sure the correct USB driver is in...

Страница 18: ...nd repair must be carried out by X2E personnel only In case of malfunctions or damages please contact X2E via e mail to get information about returning the UPoB xoraya return x2e de Disposal Within th...

Страница 19: ...ode max Vin 0 8 V at room temperature Output load current max 4 8 A Idle current max 200 mA Quiescent current max 2 mA DC voltage protection max 40 V Temperature range 40 C to 85 C RS232 Baud rate 115...

Страница 20: ...DIGITAL_IO 11 STATUS_CAN_ST_N 13 RS232_GNDIN 15 RELAIS_VCCIN Pin Function 2 COM_RS232_RXD 3 COM_RS232_TXD 5 RS232_GNDIN RS232 Pin Function 2 STATUS_CAN_ST_N 7 STATUS_CAN_ST_P CAN Pin Function 2 RS232_...

Страница 21: ...Advanced 0 7 A 37 s XORAYA V5 C20 0 9 A 28 s XORAYA Minilogger Z7 R8C4Ge2 1 A 26 s XORAYA V5 C20L4B12FAS 1 6 A 16 s 1 A 26 s 2 A 13 s 3 A 9 s 4 A 6 s 4 8 A 6 s Output load Trigger time 100 75 50 25 X...

Страница 22: ...Accuracy of values Because the stated voltages are determined empirically the values might deviate under certain circumstances Normal mode to bridge mode Bridge mode to normal mode 9 4 9 6 9 8 10 10 2...

Страница 23: ...User Manual UPoB 23 Switch on threshold Charging threshold 10 8 11 11 2 11 4 11 6 11 8 0 0 5 1 1 5 2 2 5 3 3 5 4 4 5 V Iout Vin 10 8 11 11 2 11 4 11 6 11 8 0 0 5 1 1 5 2 2 5 3 3 5 4 4 5 V Iout Vin...

Страница 24: ...AN ID Content 0x120 internal states for example DIP switch positions 0x121 output load current output voltage output power input voltage 0x122 capacitor voltage capacitor current capacitor power charg...

Страница 25: ......

Страница 26: ...X2E GmbH Jahnstrasse 2b 76870 Kandel GERMANY Phone 49 7275 9143 100 Fax 49 7275 9143 109 E Mail info x2e de Internet http www x2e de...