background image

- 10 -

MAINTENANCE

REPLACING THE HOT AIR GUN HEATING ELEMENT

Handle Cover - 

Side 1

Heating 

Element

Handle 

Cover - 

Side 2

Mica Paper

Discharge Tube

Nozzle

Retaining Cap

Circuit 

Board

Fan 

Reducer

Fan

1.  Turn off the unit and unplug it from the outlet. Allow the hot air gun 

to cool down to room temperature.  

Never attempt to handle the gun while the it is hot.

2.  Slide the ergonomic grip up and unscrew the retaining cap, pull the 

ergonomic grip down off the handle.

3.  Unscrew both of the screws at the base of the handle and separate 

the two handle sides.

4.  Pull the heating element out of the Mica Paper and Discharge 

Tube, being careful not to disconnect grounding wire.

5.  Unscrew the two screws holding the circuit board in place.
6.  Desolder the four wires to the heating element - Please take note 

of the location of the 4 wires thickness/color for installation of new 

heating element.

7.  Solder the new heating element into place.

8. 

Reassemble the hot air gun.

Содержание 6020-PRO-X

Страница 1: ......

Страница 2: ......

Страница 3: ...s 7 0 L x 6 75 W x 6 25 H Weight 7 5 lbs Working Environment 32 F 104 F 0 C 40 C Storage Environment 4 F 176 F 20 C 80 C Storage Humidity 35 45 Airflow Type Brushless DC Fan Airflow Velocity 1 5 M S A...

Страница 4: ...r any flammable substance material or gas 4 Never touch the metallic components of the hot air gun while the unit is on They are extremely hot and will cause serious burns instantly 5 Always turn the...

Страница 5: ...3 4 5 6 7 8 9 1 Temperature Display 2 Patented Quick Change Nozzle Rack 3 Temperature Adjustment Buttons 4 Air Flow Control Knob 5 Hot Air Gun Cord Receptical 6 Hot Air Gun Power Switch 7 Hot Air Gun...

Страница 6: ...ntrol Knob to adjust the airflow for the hot air gun This can be set from 20 100 CAUTION When using a temperature higher than 300 C on the hot air gun the air flow should be set at 45 or higher This w...

Страница 7: ...ug the unit or shut off the Power Switch until you have placed the hot air gun in the holder and it has cooled down and the air has stopped blowing automatically When the unit is not in operation turn...

Страница 8: ...re 2 below 3 The nozzle is then secured on the hot air gun and ready to use See Figure 3 below Figure 1 Figure 2 Figure 3 To Remove a Nozzle 1 Choose an open nozzle space on the Quick Change Nozzle Ra...

Страница 9: ...when buttons are pushed knobs are turned and when it goes into standby mode 1 Ensure the hot air gun is in the holder 2 Press and hold both the CH1 and CH2 buttons 3 The bottom display will say on or...

Страница 10: ...the hot air gun is regularly used will affect the life of the heating element and can cause fatigue When a heating element begins to fatigue the heat that is transferred to the blowing air from the h...

Страница 11: ...he unit can be calibrated 1 While the hot air gun is NOT in the holder press and hold the CH1 CH3 buttons for approximately 3 seconds 2 The temperature display will flash and the bottom display will s...

Страница 12: ...rip up and unscrew the retaining cap pull the ergonomic grip down off the handle 3 Unscrew both of the screws at the base of the handle and separate the two handle sides 4 Pull the heating element out...

Страница 13: ...the outlet Ensure that the outlet is functional Contact X Tronic International for assistance Contact information on back of manual Soldering Iron Rattles This is expected behavior The rattle is a sm...

Страница 14: ...2159 Magnum Circle Lincoln Nebraska 68522 we extend this limited warranty only to the consumer who originally purchased the product in the United States the District of Columbia or Canada you It does...

Страница 15: ...With respect to any defective product during the Initial Warranty Period we will in our sole discretion either a replace such product or the defective part free of charge or b refund the purchase pric...

Страница 16: ...ur NEW Product Seal prior to shipment Our goal is to ensure Quality Completeness and Satisfaction for your order For Any Questions Problems or Compliments please call or email us If you would like to...

Отзывы: