EasyTrax Setup and Operation
18
NOTE:
Do not shake the can before use or invert the can during use.
3.
Lower the read head back to its measurement position and verify that the release posts
snap back into position.
4.
Recalibrate the instrument by following the calibration procedure accessible from the Press
Tool screen under the connection icon.
Cleaning the Calibration Plaque
It is recommended that you clean the calibration plaque every 30 days or when noticeably dirty.
This is a relatively easy procedure requiring only a few minutes of time.
1.
Slide open the calibration plaque protective cover at the home position in the table.
2.
Clean the white calibration plaque with a cotton swab or lint free cloth.
3.
After cleaning is complete, slide the protective cover back in place.
Cotton swab
Cal plaque
Protective cover
Air nozzle