background image

Input Level control

The input level control, 5V – 0,25 V,
matches the output of your radio to
the input of the amplifier. After instal-
lation is complete, make sure the in-
put of the amplifier is turned down all
the way to 5V.

The high pass filter
blocks

 

very low

frequencies from reaching
the speakers. It is mostly
used to protect small
speakers ( like 5 inch and
smaller ) from deep bass.

High Pass filter (HPF) - All models

The low pass filter  is
mostly used for
subwoofers. It will allow
low frequencies only and
blocks higher frequencies.
A typical setting is 60 – 70
Hz.

The 

X-A10

 is a mono channel amplifier mainly

intended for use with one or two subwoofers but can
also be used in full range mode.

The amplifier has the following filters / features:

 Lowpass filter adjustable between 50 and 250 Hz,

    the filter can be switched off.

 Highpass filter selectable FULL - 70 Hz - 90 Hz.

 Internal subsonic filter fixed to 25 Hz.

 The 

XA20

 is a 2-channel amplifier. Can be used

for a pair of stero speakers or a subwoofer connted
in mono bridge mode.

The amplifier have the following filters / features:

 Lowpass filter adjustable from 50 to 200 Hz, the

    filter can be switched off.

 Highpass filter selectable FULL - 70 Hz - 90 Hz.

 Internal subsonic filter fixed to 25 Hz.

6

The 

X-A40

 is a 4-channel amplifier for use with a

front system and a subwoofer, or two front systems.

The amplifier has the following filters / features:

 Lowpass filter adjustable from 50 to 100 Hz, the

    filter can be switched off.

 Highpass filter selectable OFF - 70 Hz - 90 Hz.

   The filter can be turned off for running the amplifier
   in full range.

 Internal subsonic filter fixed to 25 Hz.

The 

X-A30

 is a 3-channel amplifier for use with a

front system and a subwoofer.

The amplifier has the following filters / features:

Stereo section (front channels):

 High pass filter selectable FULL - 70 Hz - 90 Hz.

Mono section (Sub channel):

 Lowpass filter adjustable between 50 and 100 Hz.

 Internal subsonic filter fixed to 25 Hz.

Play a CD, make sure all bass or treble settings or
equalizer are flat, and turn the volume of the radio
up until  you just start to hear distortion. Turn the
volume control down just a bit.  Increase the input
level control on the amplifier ( clockwise or to the
right ) until you just start to hear distortion, then back
the level control just a bit. Now your radio and
amplifier levels are matched.

Set the swich in position 70 Hz or 90 Hz to activate
the filter. Test which setting sounds best.
The filter can be set at 

FULL

 position if you want to

run the amplifier in full range mode without limiting
the frequency range.

Set the switch in 

ON

 po-

sition to activate the filter.
Set the switch in  

OFF

position if you want to run
the amplifier in full range
mode. X-A30 has no
switch.
The frequency range of
the LP-filter is different on
each model, see the
drawings on the right.

Subsonic filter 

 

- All models

All models include a

 Subsonic filter that

 blocks

the very deepest  frequencies from reaching the
speakers. The cutoff frequency is 25 Hz.
The filter is internally connected on all models and
can not be switched off.

Features / crossovers

Low Pass filter (LPF)

Crossovers/filters and other features
on each model

X-A20

X-A30

X-A40

X-A10

Содержание X-A10

Страница 1: ...peaker wiring Front speakers 9 Subwoofer 9 X A30 speaker wiring Two speakers and subwoofer 10 X A40 speaker wiring Four speakers 11 Two speakers and bridged subwoofer 11 Testing 12 Troubleshooting 12...

Страница 2: ...ou select a location do remember that the amplifier generates a lot of heat Choose a location where air can circulate freely around the amplifier Do not cover the amplifier with carpets or hide behind...

Страница 3: ...oard and the amplifier board to the car some extra for fuse holder amplifier ground etc Electrical insulation tape inch thick plywood or particle board for the amplifier to be mounted upon Amplifier i...

Страница 4: ...bles and speaker cables If there is no remote voltage available from the stereo you must connect to the ignition key through the radio or any accessories fuse For High Level input We recommend you to...

Страница 5: ...ity By changing the polarity of plus and minus you can change the phase X A10 20 30 On these models you connect as in this example X A30 On this model the high level signal is fed internally to SUB ch...

Страница 6: ...lectable OFF 70 Hz 90 Hz The filter can be turned off for running the amplifier in full range Internal subsonic filter fixed to 25 Hz The X A30 is a 3 channel amplifier for use with a front system and...

Страница 7: ...7 Crossovers filters and other features on each model...

Страница 8: ...er LPF is mostly used for subwoofers It will allow low frequencies only and blockshigherfrequencies A typical setting is 60 70 Hz Set the switch to ON position to activate the filter Use this position...

Страница 9: ...the speakers It is mostly used to protect small speakers like 5 inch and smaller from deep bass Set the swich in position 70 Hz or 90 Hz to activate the filter Test which setting sounds best The filt...

Страница 10: ...lifier This connection gives a 2 ohm load with two 4 ohm subwoofers The low pass filter LPF is used for subwoofers It will allow low frequencies only and blockshigherfrequencies A typical setting is 6...

Страница 11: ...et the swich in position 70 Hz or 90 Hz to activate the filter Test which setting sounds best The filter can be set at FULL position if you want to run the amplifier in full range mode without limitin...

Страница 12: ...OFF AFTER 10 30 MINU TES The amplifier is overheating due to inadequate venti lation Check mounting position is free from obstruction Do this 1 Move the amplifier to a place with better ventil ation 2...

Страница 13: ...ht battery Tap the wire on to the terminal of the battery and observe the movement of the cone The cone should move outwards when the wire touches the battery and inwards when the battery is removed I...

Страница 14: ...xD mm 72 x 255 x 358 72 x 255 x 278 Dimensions inch 2 8 x 10 x 14 2 8 x 10 x 10 9 Weight 3 kg 2 3 kg X program X A30 X A40 Number of channels 3 4 Amplifier class AB AB Power output 4 ohm 0 1 THD 2 x 5...

Страница 15: ......

Страница 16: ...DLS Svenska AB P O Box 13029 SE 40251 G teborg Sweden Tel 46 31 840060 Fax 46 31 844021 E mail info dls se www dls se...

Отзывы: