4. receiver LED
Operation
Place the instrument on the working surface or mount it on
the tripod/pillar or wall mount (comes with the instrument).
Switch on the instrument: turn the compensator switch (4) to
the position “ON”.
Press on the power key (1) as following:
1. One pressure - vertical beam
2. Two pressures - horizontal plane
3. Three pressures - both horizontal and vertical planes.
4. Four pressures – vertical and horizontal planes are ON.
TILT LED is on.
To work with detector, press button (2). This mode allows you
to work in bright illumination and at long distance.
To check the accuracy of line laser
To check the accuracy of line laser (slope of plane)
Set up the instrument between two walls, the distance is
5m.Turn on the Cross Line Laser and mark the point of cross
laser line on the wall.
Set up the instrument 0,5-0,7m away from the wall and make,
as described above, the same masrks. If the difference {a1-
b2} and {b1-b2} is less then the value of “accuracy” (see spe
-
sifications), there is no need in calibration. Example: when
you check the accuracy of Cross Line Laser the difference
is {a1-a2}=5 mm and {b1-b2}=7 mm. The instrument’s error:
{b1-b2}-{a1-a2}=7-5=2 mm. Now you can compare this error
with standard error. If the accuracy of Cross Line Laser isn’t
corresponding with claimed accuracy, contact the authorized
service center.
To check level
Choose a wall and set laser 5M away from the wall. Turn
on the laser and cross laser line is marked A on the wall.
Find another point M on the horizontal line, the distance is
around 2.5m. Swivel the laser, and another cross point of
cross laser line is marked B. Please note the distance of
B to A should be 5m. Measure the distance between M to
cross laser lune, if the difference is over 3mm, the laser is out
of calibration, please contact with seller to calibrate the laser.
To check plumb
Choose a wall and set laser 5m away from the wall. Mark
point A on the wall, please note the distance from point A
to ground should be 3m. Hang a plumb line from A point
to ground and find a plumb point B on ground. Turn on
the laser and make the vertical laser line meet the point B,
along the vertical laser line on the wall and measure the dis-
4
5
6
Содержание Helper 2D
Страница 1: ...Operating manual Line laser X Line Helper 2D...
Страница 9: ...9 Helper 2D 1 1 2 3 4 5 6 1 4 1 V H 2 3 2 4 4 1 2 3 4 3...
Страница 10: ...Helper 2D 10 2 5 180 0 5 0 7 1 2 b1 b2 1 2 5 b1 b2 7 b1 b2 1 2 7 5 2 5 2 5 4 5...
Страница 11: ...11 Helper 2D 5 2 5 3 10 4 6...
Страница 12: ...12 Helper 2D EMC 2 2 DIN IEC 60825 1 2007 EN60825 1 2007 II CFR 21 1040 FDA 2 7...
Страница 13: ...13 Helper 2D...