In User PROGRAM mode, user may press ▲/▼ to select program drawing
(
each timer shift
corresponding Level value), display and flash in the inserted drawing. It will light after setting.
When setting, the figures and Letters in LOAD Window displaying to be set. LOAD value flash
at 1Hz. Press mode to confirm the value after setting. A complete PROGRAM drawing timer
shift has 20 steps need to be set. Then it will run as the set program. When come to 9
th
step, it
scroll and shift to lest and so on. If you want to pause the program halfway, press mode 2s.
The unset timer shift will save last time value.
WATT
When entering, the WATT value is flashing to be set(preset value=120). User press ▲/▼to set
WATT value. After Starting, it will adjust automatically according to the WATT value user
inserted and exercise status.
SLEEP MODE
No signal(SENSOR, KEYBOARD, PULSE value display) input over 4 minutes, system will
enter SLEEP MODE. All set and calculated value will be saved. When power on and start
next time, it will go on with the calculated value.
FUNCTION
TIME
Display range 0:00~99:99 ; Setting range 0:00~99:00
DISTANCE
Display range 0.00~99.99 ; Setting range 0~99.90km
CALORIES
Display range 0~9999 ; Setting range 0.00~9990
PULSE
Display range P-30~230 ; Setting range 0-30~230
WATT
Display range 0~999 ; Setting range 10~350
SPEED
0-99.9KM
RPM
0~999
INSPECTION FOR ABNORMAL CONDITION
LCD display E-2: Inspect the electronic watch and console 5PIN connecting cable for
peeling
off and poor contact.
LCD no drawing:
1. Check whether the adapter is well inserted into the AC plug seat.
2. Check the adapter DC pin is plugged into the machine or not, whether contact poorly.
3. Check the electronic watch and console 12 PIN connecting cable for peeling off and
poor contact.
4. Check DC JACK connecting cable is loose or not.
5. Check the internal 12PIN connecting cable of the electronic watch is loose or not.