Loading Spray Material Into The 

Sprayer

Spraying solution can be loaded by either filling with a 

pre-mixed solution or mixing the chemical and carrier on 

the sprayer. Most trailer mounted sprayers have a Mix n’ 

Fill tank mounted on the trailer while most 3 point sprayers 

use the Mix n’ Fill tank on the nurse trailer.

Always wear protective clothing, i.e. apron, face 

shield, gloves and respirator, when handling any 

chemicals. Failure to do so will risk chemical expo-

sure to your body resulting in sickness, injury or 

possibly death.

3 Point Carrier:

3 point carriers may be equipped with an optional “Quick 

Fill”.  Remove  the  cap  from  the  spray  tank  “Quick  Fill” 

coupling and attach the supply hose to the coupling. Open 

the “Quick Fill” ball valve as well as the supply line. Fill 

the spray tank with water or mixed solution.

If you are mixing the chemical in the spray tank, carefully 

add the desired amount of chemical to the spray tank. 

Turn the pump on and allow the agitator to circulate the 

chemical for several minutes.

Trailer Sprayers:

Remove the cap from the “Quick Fill” coupling on the Main 

Fill valve and attach the supply hose to the coupling. Open 

the main fill ball valve as well as the main tank ball valve. 

Make sure that the Mix-n-Fill valve is closed. Open the 

supply line. Fill the spray tank with water, less the amount 

of chemical to be added. (The Ace pump can be used to 

fill the tank by closing the main valve and opening the filler 

and return valve.)

The  EP-1000  spray  trailer  is  equipped  with  a  Mix-n-Fill 

tank  mounted  in  the  trailer  tongue  while  the  HCS-500T 

spray trailer has the Mix-n-Fill tank mounted on a parallel 

linkage frame. 

EP-1000 Trailer Mix-n-Fill:

With the Mix-n-Fill valve closed, add the desired amount 

of chemical to the Mix-n-Fill tank. 

Open the agitator and return lines, then engage the pump. 

Close the spray tank ball valve about halfway to “starve” 

the pump slightly. Open the Mix n’ Fill ball valve to allow 

the chemical to be drawn into the pump. Close the Mix 

n’ Fill ball valve once the tank is empty to prevent an air 

leak on the suction side of the pump. With the return ball 

valve open, let the pump circulate the solution for several 

minutes. Rinse the Mix n’ Fill tank and draw the rinse water 

into the spray tank. 

Figure B2

Filling Spray Tank

Operation

< fill valve open

< main valve open

Figure B3 

 Adding Chemical to EP-1000 Mix-n-Fill Tank

Figure B1

Filling Optional “Quick Fill”

fill hose >

fresh water valve closed >

Mix-n-Fill valve closed >

Содержание 8220 Boom

Страница 1: ...Operator s Parts Manual 8420 VSB 8220 Boom Printed In The USA Specifications Design Subject To Change Without Notice 4 1 18 05 08R4...

Страница 2: ...o the LIMITED WARRANTY Polyethylene and fiberglass tanks These tanks are warranted for the storage and transport of water herbicide solutions on farm liquid fertilizer and liquid feed Such tanks shoul...

Страница 3: ...Number Trailer Serial Number Boom Serial Number Pump Model Wylie Invoice Number Owner s Name Address City State Zip Phone Email Dealer Owner s Signature Must be returned within 10 days to validate the...

Страница 4: ......

Страница 5: ...oom Plumbing 28 EP 1000 Trailer 29 HCS Trailer 30 LCS Tandem Trailer 31 32 LCS Single Trailer 33 3 Point Carrier Frame 34 3 Point Centrifugal Pump Plumbing 35 EP 1000 HCS Pump Plumbing 36 EP 1000 HCS...

Страница 6: ...ions or procedures are described Before Use Do not operate sprayer until this manual has been read and understood Thoroughly read and understand all instructions before operating this sprayer If you h...

Страница 7: ...connections prior to starting engine or pressurizing line If any fluid is injected into the skin obtain medical treatment immediately to avoid gangrene Operator s Instructions Securely fasten seat be...

Страница 8: ...4 Decal SW700 Decal V9055 Decal T3 Safety Decals Placement Safety Issues Vari Space Boom VSB Decal SW701W...

Страница 9: ...5 Safety Decals Placement Safety Issues Decal SW202 Decal SW700 Decal T3 8420 Boom Decal V9055...

Страница 10: ...6 Safety Decals Placement Safety Issues Decal SW700 HCS LCS Trailers Decal V9055 Decal SW701W...

Страница 11: ...d refer to the instructions for the VSB and apply them to the 8220 boom This manual explains where and how to make necessary adjustments to your sprayer for safe and proper operation Thoroughly read a...

Страница 12: ...ic hoses if equipped to tractor hydraulic circuits Adjust the top link to level the sprayer when the boom is at spraying height Move the tractor to a flat area with sufficient clearance to unfold the...

Страница 13: ...r Remcor controller refer to the appropriate manual for detailed instructions on setting thecontrollerupforoperation Theconsoleshouldbemounted in a convenient location in the tractor cab for easy acce...

Страница 14: ...aulic Drive Note The hydraulic fluid flow supplying the pump must be set the first time the pump is engaged and anytime a different hy drauliccircuitortractorisused Beforeengagingthepump turn the hydr...

Страница 15: ...on to open the boom valves automatic controller should be set to manual and flush the boom with clear water Turn the pump off once the boom is flushed Roller Pump PTO Drive With the agitator line open...

Страница 16: ...to the coupling Open the main fill ball valve as well as the main tank ball valve Make sure that the Mix n Fill valve is closed Open the supply line Fill the spray tank with water less the amount of c...

Страница 17: ...ix n Fill tank should always be empty except when adding chemical to the sprayer Raising and low ering the tank with chemical is dangerous and greatly increases the possibility of chemical exposure to...

Страница 18: ...o allow the boom to self level during operation The boom must always operate perpendicular to the ground Failure to do this can cause excessive yaw movement and can damage the boom Levelling Trailer S...

Страница 19: ...k agitator and return line ball valves then open the fresh water tank valve Set the con troller for manual operation engage the pump and open the boom valves to allow fresh water to flush the pump and...

Страница 20: ...information provided by chemical manufacturer for proper handling procedures 1 Turn ball valve off Remove the strainer s base and take out wire mesh screen Clean and replace Turn ball valve on 3 Disca...

Страница 21: ...m Sections Figure C4 Wing Adjustment Points 1 If the primary wing needs to fold out more remove the pin from the rod end of the folding cylinder and lengthen the cylinder clevis If the primary wing ne...

Страница 22: ...lock the pins Figure C8 HCS Tandem Axle Adjustment Figure C7 Adjust Hitch To Level Trailer Adjustment EP 1000 and HCS Spray Trailer The EP 1000 trailer is equipped with a 1 000 gallon tank and 12 5L x...

Страница 23: ...or cut components Apply thread sealant to pipe threads 6 Close ball valve 7 See pump ow ner s manual or contact Wylie Spray Center 8 Close fresh w ater tank valve 9 Adjust tractor flow higher Controll...

Страница 24: ...tibility 1 Open agitator ball valve 2 Replace agitator assembly 3 Mix a small sample in a 5 gal bucket first Problem Cause Solution Boom not level 1 One end of boom w eighted w ith mud etc 1 Clean boo...

Страница 25: ...21 Recommended Lubrication Suspension Arm 2 grease zerts per arm Grease every week Folding Chains Oil every week Walking Beam Pivot Grease every week Wheel Hub Assemblies Repack every year Lubrication...

Страница 26: ...22 Notes Notes...

Отзывы: