Wyco SELECT-Cycle SC1430 Скачать руководство пользователя страница 7

TROUBLESHOOTING

Symptom

Possible Cause

Solution

Ground Fault Interrupter (GFI) repeatedly 

trips

Short in wires between 

high-cycle head and 

switch

Remove head and check wires for wear  Repair as 

required

Short in internal high-

cycle motor

Replace high-cycle motor stator assembly

Short in high-cycle cord 

or plug Internal drive has 

tripped

Replace cord or plug

Vibrators stop while power is still applied 

to converter and rotary switch is not off

Internal drive has tripped

Unplug converter for two minutes and plug back in 

to reset  If the problem persists, have error code on 

drive checked by a qualified electrician/personnel  

Refer to drive manual for resolution

Vibrators do not come up to full speed 

and converter trips after 2 minutes

Some lower voltage 

power sources cannot 

start two vibrators at 

once

Follow start up procedure in order by powering 

drive and turning it to desired speed before turning 

on vibrators

Fuses on converter input have blown

Excess current applied to 

power drive

The drive will internally shut down when most 

problems occur  If the fuses blow it is an indication 

of a serious problem and the converter should be 

returned to the factory  The high-cycle vibrators 

should also be thoroughly inspected

Troubleshooting

Page 7 

December 2018

VBR-UM-02429-EN-03

Содержание SELECT-Cycle SC1430

Страница 1: ...Converter SELECT Cycle VBR UM 02429 EN 03 December 2018 User Manual ...

Страница 2: ... and Symbols 3 Safety Rules and Precautionary Measures 3 Hazardous Voltage 3 Servicing Information 3 Power Source 4 Environment 4 Description and Features 5 Operation 5 Startup 5 Shutdown 5 Drawing and Parts List 6 Troubleshooting 7 Converter SELECT Cycle Page ii December 2018 VBR UM 02429 EN 03 ...

Страница 3: ...pable of causing death or serious personal injury Indicates a hazardous situation which if not avoided could result in severe personal injury or death Indicates a hazardous situation which if not avoided is estimated to be capable of causing minor or moderate personal injury or damage to property Safety Rules and Precautionary Measures Read understand and follow all of these instructions before us...

Страница 4: ...not damaged before connecting equipment Power Source CHOOSE THE APPROPRIATE AC POWER SOURCE 230V SINGLE PHASE 50 60 HZ FOR THE INPUT POWER THIS CONVERTER Environment This converter should only be used in a well ventilated environment which will allow heat to dissipate This will prevent potentially damaging heat build up internally Do not use in ambient temperatures greater than 105 F 40 C Keep awa...

Страница 5: ... Terminal Purpose White X 115V AC Black Y 115V AC Green G Ground Not Used W Not Used The frequency of the supplied voltage determines the speed of high cycle vibrators This converter outputs three frequencies 133 180 and 200 Hz These frequencies correspond to vibration speeds of 8000 10 800 and 12 000 vpm Select this speed with the SELECT Cycle rotary switch which can also be switched to the OFF p...

Страница 6: ...DRAWING AND PARTS LIST Drawing and Parts List Page 6 December 2018 VBR UM 02429 EN 03 ...

Страница 7: ...oblem persists have error code on drive checked by a qualified electrician personnel Refer to drive manual for resolution Vibrators do not come up to full speed and converter trips after 2 minutes Some lower voltage power sources cannot start two vibrators at once Follow start up procedure in order by powering drive and turning it to desired speed before turning on vibrators Fuses on converter inp...

Страница 8: ...ements Badger Meter reserves the right to change product or system specifications without notice except to the extent an outstanding contractual obligation exists 2018 Badger Meter Inc All rights reserved Wyco Tool 8635 Washington Avenue Racine WI 53406 3738 USA wycosales wycotool com www wycotool com Phone 262 639 6770 Fax 262 639 2023 Legacy Document Number W510 ...

Отзывы: