background image

4

READ AND FOLLOW ALL INSTRUCTIONS

CAUTION:  The Eclipse IT Iris mechanical dimmer/dowser has been
designed to withstand the rigors of entertainment lighting. However, the

teflon coating on the Iris blades can only withstand temperatures up to 600

°

F.

When used with some excessively hot fixtures, degradation and possibly
flaking of this coating may occur.

USE WITH EXCESSIVELY HOT FIXTURES – OVER 700

°

F AT THE IRIS

BLADES – THAT RESULTS IN DEGRADATION OF THE HIGH TEMP
POWDER COATING IS EXCLUDED FROM THE PRODUCT WARRANTY.

This manual gives step-by-step instructions for preparation, setup, and
operation of the Eclipse IT Iris dowser.

There is a potential risk of fire, electric shock, or injury to persons if the
product is not used as instructed.

The Eclipse IT Iris dowser is to be used in an indoor environment only and is
not intended for residential use.

Содержание 87250

Страница 1: ...1 Eclipse IT Iris User Manual ...

Страница 2: ...Operating Modes 7 Signal and Power 7 Fan Speed Control 7 Installing the Eclipse IT Iris 8 Menu Tree 10 Alerts Error Messages 12 DMX Address 13 Settings 14 Sensor Info 14 Self Test Demo 15 History 15 Reset Defaults 16 Head Feet Restrictions 17 Equipment Compatibility 18 Cables 18 Non RDM Equipment and Infotrace 19 Coloram IT Products and Standard Environments 19 Specifications 20 Parts List 21 Info...

Страница 3: ...3 Safety Notice SAVE THESE INSTRUCTIONS ...

Страница 4: ...ng of this coating may occur USE WITH EXCESSIVELY HOT FIXTURES OVER 700 F AT THE IRIS BLADES THAT RESULTS IN DEGRADATION OF THE HIGH TEMP POWDER COATING IS EXCLUDED FROM THE PRODUCT WARRANTY This manual gives step by step instructions for preparation setup and operation of the Eclipse IT Iris dowser There is a potential risk of fire electric shock or injury to persons if the product is not used as...

Страница 5: ...ontinue on to additional PS power supplies or other DMX controlled devices The power supply sends power DMX control signal and RDM information on a single cable eliminating the need for a separate power cable for the dowser Eclipse IT Iris dowsers are 100 compatible with all products of the Coloram IT family including Coloram IT and CXI IT color changers PS Power Supplies and Eclipse IT Shutter do...

Страница 6: ...t have Infochip installed to the Infogate hardware and software Refer to the Infogate and Infochip manuals for details E Using Infogate i Initiate Perform Discovery ii In the DMX Map drag and drop the DMX address for the Eclipse to DMX address 1 F Refer to the Infogate user manual for further details 2 Send DMX Levels A On the lighting console vary the level of the Eclipse DMX channel to open and ...

Страница 7: ... positioning Press the button to open the fins and the button to close them The wired pendant cable can be up to 1 000 feet long Self Test Demo Mode The dowser unit can be controlled by the menu buttons on the dowser unit Please refer to the Menu Details below under Self Test Demo for details Signal and Power The Eclipse uses a PS Power Supply with Coloram IT cables for DMX signal RDM communicatio...

Страница 8: ...ecide which mounting method best suits your application The power supply comes with a mounting bracket which hooks over the pipe or truss of your lighting rig and is then locked into place with a thumb screw If you have selected this mounting method connect the safety cable by running it around the pipe or truss to which the power supply is attached 90 25 0 VA C 50 60 HZ 4 AM P SL O B L O AT 11 5 ...

Страница 9: ...lt and is not covered by product warranty 6 Connect the DMX512 source Connect the DMX512 signal source to the DMX input connector on the back of the power supply using standard DMX cable Valid DMX signal will be indicated by a flashing green LED The dowsers will now open and close their fins according to their respective DMX signal levels Alerts Menu DMX Status DMX Address 512 Settings Sensor Info...

Страница 10: ...s Cleaning Info SINCE CLEAN RESET 287 HR Reset Like New Needs Cleaning Maintenance Info SINCE MAINT RESET 287 HR Reset Like New Needs Maint RESET No Yes MAINTEANCE HOURS GAUGE Reset RESET No Yes CLEANING HOURS GAUGE Reset Alerts Menu DMX Status DMX Address 512 Settings Sensor Info History Reset Defaults Local Control Self Test Demo Mode Now 00 1A High 00 2A Low 00 1A Reset hi Low No Yes Pass Thru ...

Страница 11: ...row buttons to move to the correct address 5 Press SELECT to save the address Alerts Error Messages The following is an explanation of alerts and error messages that are displayed locally on the dowser To read alert messages 1 When SENSOR ALERT is displayed press SELECT 2 As an example VOLTAGE ALERT indicates a voltage problem 3 Press SELECT to access more information on the Voltage Alert 4 For ex...

Страница 12: ...T OPERATING PROPERLY Check Eclipse fan for any maintenance needs RESET ALERT Clears existing alert from display screen when you press SELECT unless problem still currently exists MULTIPLE ALERTS 1 Press SELECT to read the first alert 2 Press SELECT to read the details of the first alert 3 Press BACK to view the second alert 4 Press SELECT to view details of the second alert 5 Press BACK to check i...

Страница 13: ...tting Sensor Info VOLTAGE 1 Displays present voltage and highest and lowest voltages measured along with normal minimum and maximum acceptable voltages Reset Hi Low A Use the arrow buttons to select Yes B Press SELECT to activate Reset Hi Low PASS THRU CURRENT 1 Displays present pass through current and highest and lowest current measured along with normal minimum and maximum acceptable pass throu...

Страница 14: ...ing means cleaning dust out of the vent slots off the printed circuit board and off the internal components C The display also shows the number of hours since the last cleaning of dowser Reset Hours i Press SELECT to select the Reset Hours function ii Use the arrow buttons to select Yes on the Reset Cleaning Hours Gauge iii Press SELECT to activate Reset Cleaning Hours Gauge Maintenance Info A Lif...

Страница 15: ...Lamp A Press SELECT to display the gauge that indicates the number of hours that the lighting fixture lamp has been on since its lamp was installed Figure 7 Reset Hours i Press SELECT to select the Reset function ii Use the arrow buttons to select Yes on the Reset Host Light Lamp Hours Gauge iii Press SELECT to activate Reset Host Light Lamp Hours Gauge Reset Defaults 1 Press SELECT to select Rese...

Страница 16: ...ower supply and the first Eclipse Iris IT is 100 feet long The cable between the first and the second Eclipse is 20 feet long and the cable between the second and third Eclipse is also 20 feet long The amount of cable from the power supply to 1st Eclipse IT Iris 100 ft 2nd Eclipse IT Iris 120 ft 3rd Eclipse IT Iris 140 ft Total 360 head feet Head Feet Limits 1K 7 5 Eclipse IT Iris Model 87250 1 50...

Страница 17: ...ded pair The shells of the two XLR connectors are not electrically connected this prevents high power currents from flowing from chassis to chassis of the equipment The twisted pair shield is connected only at the male XLR connector end This is the standard Wybron power data Cable XLR Pin Wire Color Function Size 1 White Ground 14 AWG 2 Green Data 22 AWG 3 Red Data 22 AWG 4 Black 24 Volts DC 14 AW...

Страница 18: ...onfiguration status monitoring and management of RDM devices in such a way that does not disturb the normal operation of the DMX devices that do not recognize the RDM protocol Coloram IT and Standard Non RDM Environments The Coloram IT family of products Coloram IT CXI IT Eclipse IT Iris and Eclipse IT Shutter which all must be connected to PS power supplies will work in any standard environment t...

Страница 19: ...mmon to close the fins Pin 3 Common Current Requirements 1K 7 5 10 2K 12 24 1 0 Amp 24 VDC Fuse 1K 7 5 10 2K 12 24 1 5 amp Slo Blo Mounting Plates Various plates available to fit a wide variety of fixtures Please refer to Wybon s Web site at www wybron com for details Fan Small low speed fan to cool the electronics enclosure Safety Cable 3 5 feet long cable included Daisy Chaining Individual DMX a...

Страница 20: ...y of the following items contact an authorized WYBRON dealer Or go to www wybron com Eclipse IT Iris Dowsers and Power Supplies 87250 1K 7 5 Eclipse IT Iris Dowser 810060 10 Eclipse IT Iris Dowser 812020 2K 12 Eclipse IT Iris Dowser 823020 24 Eclipse IT Iris Dowser 820150 PS 150 Power Supply 150 watts 820300 PS 300 Power Supply 300 watts 820600 PS 600 Power Supply 600 watts 20250 PS 450i Power Sup...

Страница 21: ...ets and Accessories 715 01 03P PS 150 300 600 Power Supply hanger bracket SCRWC252075 Wing screw for Power Supply hanger bracket to pipe SCRSC2520037 Socket cap screw for hanger bracket to Power Supply 11010 1 Control Pendant ...

Страница 22: ... performance IT Products Coloram IT CXI IT Eclipse IT Shutter and Eclipse IT Iris all have updated electronics to support RDM communication plus additional product improvements including sensors to detect a variety of conditions The heart of the Infotrace IT system is Infogate specialized software and hardware that uses the feedback protocol Remote Device Management RDM to facilitate remote addres...

Страница 23: ...me Infotrace provides the ability to Automate the setup of DMX addresses no more manual setting of DIP switches Proactively check the condition of equipment before during and after a show Track lamp duty cycles to predict lamp failures before they happen Predict maintenance on equipment Sensors Aperture Light Sensor Detects if the fixture s lamp is on Voltage Sensor Reports the head voltage level ...

Страница 24: ...mm red LED 13 1 2060 02 0011 Circuit card 14 1 NC5MP 5 pin chasis MT male 15 8 NC4FD L1 4 pin chasis MT female 600W 16 20 SCRFH440037 Flat head screw 17 1 NC5FP 5 pin chasis MT female 18 1 031 1666 Fuse cap round 19 1 313 007 Fuse 7 amp 20 1 031 1693 Fuse holder body 21 2 SCRFH632037 3 8 Flat head 22 1 10EEA1 Power connector filter 23 4 SCRPH440037 Pan head screw 24 1 F0825 Fan 600W 25 1 2060 01 0...

Страница 25: ...25 2 1 3 4 5 6 8 11 10 9 7 ...

Страница 26: ...26 13 14 15 12 19 18 17 16 21 20 27 26 25 24 23 22 ...

Страница 27: ...27 28 34 33 32 31 30 29 ...

Страница 28: ...or written authorization WYBRON INC shall not be responsible for any incidental general or consequential damages to property damages for loss of use time profits or income or any other charges The owner s obligations during the warranty period under this warranty are to notify WYBRON INC at WYBRON INC s address within one week of any suspected defect and return the goods prepaid to WYBRON INC at t...

Страница 29: ...29 Revision History Version Author Date Description 2 0 John Tabor 2 10 09 Model numbers ...

Отзывы: