If TXPower = 0x80, there is no value available.
If Device name length = 0, then there is no device name available.
7.1.3.1. Example 1
Request for the
of the devices found during the last scan.
Start signal
Command
Length
CS
0x02
0x0B
0x00 0x00
0x09
Response:
Start
signal
Command
| 0x40
Length
Status
#Devices
Payload
CS
0x02
0x4B
0x1E 0x00
0x00
0x02
0x11 0x00 0x00 0xDA
0x18 0x00
0xE2 0x04
0x05
0x4D 0x4F 0x44
0x20 0x31
0x55 0x00
0x00 0xDA 0x18 0x00
0xE5 0x00 0x05
0x4D
0x4F 0x44 0x20 0x32
0x11
During the last scan two devices have been detected:
• Device 1 with
0x11 0x00 0x00 0xDA 0x18 0x00
, RSSI value of 0xE2 (-30 dBm),
TXPower of 0x04 (=+4 dBm) and device name of length 5 with the value of 0x4D4F442031
("
MOD 1
").
• Device 2 with
0x55 0x00 0x00 0xDA 0x18 0x00
and RSSI value of 0xE5 (-
27 dBm), TXPower of 0x00 (0 dBm) and device name 0x4D4F442032 ("
MOD 2
") of
length 5.
7.1.4. CMD_RSSI_IND
This telegram indicates the reception of an advertising packet sent by another Proteus-II mod-
ule. It can be used to realize a position sensing application. This data can only be received,
when the module is in
ACTION_SCANNING
mode (passive scan is sufficient) and the correspond-
ing Bit in the
is set.
Besides the
, the RSSI value of the advertising packet and the transmission power of
Order code 2608011x24010